NOTE
Do not turn off POWER supply disconnecting device! The battery must
only be replaced by qualified personnel.
Alarm 30003
Fault fuse 24V DC
Cause
A fuse in the control cabinet has
tripped.
Alarm 30009
Compressed air missing
Cause
The pressure switch has been
triggered due to lack of compressed
air (< 6 bar).
Alarm 30016
No control voltage
Cause
Control voltage is missing.
Version 1.0
8--6
Action
Check fuses.
Action
Eliminate the cause of lack of com-
pressed air.
Ensure that the pressure lines and
connections are tight.
The air pressure gauge must read at
least 6 bar.
Action
Unlock the EMERGENCY STOP but-
ton.
Close guard door.
Switch on the control voltage.
Troubleshooting
SV 125
4016589