Operation
SV 125
4016589
Determining the setpoint position by moving the axis directly to the position
Touch control field
1
tion.
If the servo axis is correctly positioned, read off the current position.
2
Enter the current position on the respective Format input screen.
3
Control field
The vacuum of the pick- -up station is switched on or off.
The swivel--arm of the pick- -up station is swivelled into the indicated
position.
The swivel--arm of the pick- -up station is swivelled into the indicated
position.
The swivel--arm of the pick- -up station is swivelled into the indicated
position.
The servo axis is moved.
It moves as long as the control field is touched.
The servo axis moves in the indicated direction as long as the control
field is touched.
The servo axis moves in the indicated direction as long as the control
field is touched.
Screen Format input - - Alarm active is called up.
Screen Main screen is called up.
The previous screen is called up.
or
to move the servo axis to the desired posi-
Function
Version 1.0
5--141