Troubleshooting
SV 125
4016589
Alarm 92000
Waiting for tub discharge
Waiting for tub infeed
Cause
The SV 125 is ready to operate and
is waiting for a tub on the indicated
position.
A tub is jammed.
A tub has been removed.
Alarm 92221
Waiting for downstream machine
Cause
The downstream machine is not
ready to operate.
Alarm 92221
Waiting for I/O Communication PLC
Cause
Waiting for the connection between
PLC and input/output card.
Action
Ensure tub feeding.
Clear jamming.
The message is reset automatically
when the tub arrives at the indicated
position.
Action
Startup downstream machine.
The function can be bypassed in
menu Service - - General (function
"Release downstream machine").
Action
Wait until the connection is estab-
lished.
When the connection is established,
the message is removed.
Version 1.0
8--25