Inova SV 125 Operating Manual page 211

Fully automatic filling and closing machine for syringes
Table of Contents

Advertisement

Operation
SV 125
4016589
Y- -axis:
No. of syringes
Number of syringes per row in Y--direction.
1. stopper row / 1. syringe [mm]
Position of the first syringe in the first stopper row of the nest.
1. stopper row / 2. syringe [mm]
Position of the 2nd syringe in the 1st stopper row of the nest.
Distance (1. nest row) [mm]
Display of the syringe distance in the first row. The value is calculated automatically.
2. stopper row / 1. syringe [mm]
Position of the 1st syringe in the 2nd stopper row of the nest.
2. stopper row / 2. syringe [mm]
Position of the 2nd syringe in the 2nd stopper row of the nest.
Distance (2. nest row) [mm]
Display of the syringe distance in the second row. The value is calculated automat-
ically.
Changing a parameter
Determine the values through teach--in, see chapter 5.2.60, page 5--137.
1
Touch the input field of the parameter that should be changed.
2
Enter the determined value on the keyboard.
3
Touch control field
4
on the keyboard to take over the entry.
Version 1.0
5--125