Operation
SV 125
4016589
Call up screen 691 and enter the lowest position of the filling needle on input
6
field "Lower position".
Select input field "Upper position" and enter the upper position of the filling
needle (above the syringe).
Enter the noted values for step points 1 through 3 one after the other on input
7
field "Step point no.". Assign to each step point the curve of the fill volume
on input field "Segment type".
5.2.46.2
Adjusting the needle stroke
Preparatory operations
A spillage tray is positioned under the filling station to collect the product that
S
is emerging from the filling needles.
Mode of procedure
Enter the upper position of the filling needle outside the syringe on input field
1
Upper position. Determine the value through teach--in.
Enter the lowest position of the filling needle inside the syringe on input field
2
Lower position. Determine the value through teach--in.
Enter the position where the filling starts on input field Start dosage position.
3
Enter the position where the filling ends on input field End dosage position.
4
Touch control field
5
checked and the values must be corrected, if necessary.
to start a test filling. Then, the test filling must be
Version 1.0
5--97