Mode of procedure
Precondition is machine standstill.
1.2.2.1

POWER supply disconnecting device

Set POWER supply disconnecting device to OFF "0".
S
The display must be blank.
1.2.2.2

Compressed air supply disconnecting device

Turn off compressed air supply disconnecting device.
S
Message "Compressed air missing" is displayed.
The machine cannot be started.
1.2.2.3

EMERGENCY STOP buttons

Press each EMERGENCY STOP button individually.
S
Message "EMERGENCY STOP pressed" is displayed.
The machine cannot be started.
1.2.2.4

Guard doors

Open each guard door individually.
S
Message "Guard door open" is displayed.
The machine cannot be started.
Version 1.0
1--8
Safety regulations
SV 125
4016589