Inova SV 125 Operating Manual page 358

Fully automatic filling and closing machine for syringes
Table of Contents

Advertisement

Alarm 65014
Value out of tolerance range vacuum leak test filling system
Value out of tolerance range vacuum leak test stopper system
Cause
Leakage during leak test.
Alarm 71541
Setpoint value not reached vacuum tank filling
Setpoint value not reached vacuum tank stopper setting
Cause
Setpoint value not reached at va-
cuum tank.
Alarm 90100
Min. accumulation stopper lane 1
Min. accumulation stopper lane 2
Min. accumulation stopper lane 3
Min. accumulation stopper lane 4
Min. accumulation stopper lane 5
Cause
No or not sufficient stoppers in the
indicated lane of the stopper feeding
system.
No or not sufficient stoppers in the
sorting bowl.
Version 1.0
8--24
Action
Search and eliminate the position of
the leakage.
Action
Check parameters.
Check vacuum tank.
Action
Ensure that sufficient stoppers are
supplied.
Refill stoppers in the sorting bowl.
Eliminate possible stopper jam in the
stopper feeding system.
Troubleshooting
SV 125
4016589