Alarm 30029
Operation requested remove object nest from transfer station
Cause
Nest present on indicated position.
Alarm 30035
Lamp test active
Cause
After switching on the machine, the
lamps are tested.
Alarm 30081
Tub missing pick- -up station
Cause
Tub missing.
Alarm 30100
Emergency Stop pressed
Cause
An EMERGENCY STOP button has
been pressed.
Version 1.0
8--8
Action
Take out nest.
Action
When the lamp test has ended, reset
the message.
Action
Search and eliminate the cause of
fault.
Action
Eliminate the cause of fault.
Unlock the EMERGENCY STOP but-
ton.
Switch on the control voltage.
Troubleshooting