AH06XA-5A
Electrical specifications
Module name
Number of analog
inputs
Number of analog
outputs
Analog-to-digital
conversion
Supply voltage
Connector type
Conversion time
Isolation
Weight
Functional specifications for the analog-to-digital conversion
Analog-to-digital
conversion
Rated input range
Hardware input
-10.1 V~10.1 V -0.1 V~10.1 V
range
Fiducial error
(Room
temperature)
Fiducial error (Full
temperature
range)
Linearity error
0 mA~20 mA
-0.2 mA~20.2 mA
4 inputs
2 outputs
Voltage input/Current input/Voltage output/Current output
24 V DC (20.4 V DC~28.8 V DC) (-15%~+20%)
Removable terminal block
150 us/channel
An analog circuit is isolated from a digital circuit by a digital integrated circuit/an
optocoupler, but the analog channels are not isolated from one another.
Isolation between a digital circuit and a ground: 500 V DC
Isolation between an analog circuit and a ground: 500 V DC
Isolation between an analog circuit and a digital circuit: 500 V DC
Isolation between the 24 V DC and a ground: 500 V DC
210g
-10 V~10 V
0 V~10 V
Current output
4 mA~20 mA
3.8 mA~20.2 mA
±0.06%
±0.07%
±0.01%
±0.01%
16 bits
≦550 Ω
AH06XA-5A
Voltage input
±5 V
0 V~5 V
-5.05 V~5.05 V -0.05 V~5.05 V 0.95 V~5.05 V
±0.1%
±0.45%
±0.07%
1 V~5 V