A H 5 0 0 O p e r a t i o n M a n u a l
which has been assigned to the module can not be used. If users want to delete the data register address
in the Address cell for a parameter, they can open the Addr
the data register address in the window.
If the color of the Address cell for a parameter is gray, users can not set a data register for the parameter.
In the example below, the values of these parameters are binary values. The states of certain bits in the
data register set in the Address cell for the first parameter correspond to these parameters. Please refer to
the documents for the modules for more information about the relation between parameters and the states
of the bits in data registers.
Monitor
After users click Monitor Table on the Option menu in HWCONFIG, they can access a module through
the data registers in the Monitor Table window. As a result, if a data register is set for a parameter in a
module, and the checkbox in the Monitor cell for the parameter is selected, the data register specified will
be displayed in the Monitor Table window after the Monitor Table window is opened. The checkbox in the
Monitor cell for a parameter to which no data register is assigned can not be selected.
In the example below, D3000~D3003 are assigned to the parameters, but only D3000 and D3001 are
monitored. As a result, only D3000 and D3001 will be displayed in the Monitor Table window after the
Monitor Table window is opened. Please refer to section 8.4.6 for more information about Monitor Table
in HWCONFIG.
Initial
Users can set initial values in this column. When the parameters in HWCONFIG are downloaded, the initial
values set are written into the module. Users may need to type initial values in the Initial columns for some
of the parameter types, and select initial values in the Initial columns for the other parameter types. Please
refer to the instructions for a module for more information about the range of values which can be set, and
the processing mechanism after the downloading of the initial values.
Comment
After users click the Comment cell for a parameter, they can type a comment on the parameter. A
comment is composed of 32 characters at most, and a Chinese character occupies two characters. The
default contents of the Comment column for a parameter type are usually the same as the contents of the
Description column for the parameter type.
ess window in the same way, and delete
8 - 5 5