Delta Electronics AH500 Operation Manual page 366

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

A H 5 0 0 O p e r a t i o n M a n u a l
Completion of reading: The master station finishes reading data form a slave station
Completion of writing: The master station finishes writing data into a slave station.
Additional remark:
If the reading of data and the writing of data are synchronous, the related flags will be controlled in the
ways described below.
The master station stops reading
data and writing data
simultaneously, or the master
station is reading data and writing
data simultaneously.
The master station finishes reading
data and writing data
simultaneously.
Timeout
The master station can not produce
a packet which will be sent.
The data sent by a slave station can
not be stored in the master station.
3.
Description of the setting of the parameters related to a PLC Link:
The setting of the parameters related to a PLC Link is described below. (Suppose the master station and
slave station 1 are AHCPU530-EN.) The data in the device addresses starting from D100 in slave station 1
is read into the device address starting from D9 in the master station. The number of data read from slave
station 1 is 10. The data in the device addresses starting from Y0.0 in the master station is written into the
device addresses starting from Y2.0 in slave station 1. The number of written into slave station 1 is 5. The
slave station type is AHCPU530-EN (16#E001). The slave station address is 16#0001.
Item
Start address in the
master station
Start address in slave
station 1
Number of data read
from slave station 1
Number of data
written into slave
station 1
Slave station type
Slave station address
Device type
Additional remark:
There are a variety of Delta PLCs. Users can construct a PLC Link by connecting AH500 series CPU
modules to DVP series PLCs, and other models. Consequently, there are limitations on the devices which
can be used, the data exchange which can be performed, and the number of data which can be
exchanged.
11 - 2 2
Read error
OFF
OFF
ON
ON
ON
Reading/Writing
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Reading
Writing
Completion
Write error
of reading
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
Device code
SR1404
SR1405
SR1468
SR1469
SR1532
SR1533
SR1596
SR1597
SR1660
SR1692
SR1724
SR1756
SR1340
SR1372
Completion
of writing
OFF
ON
OFF
OFF
ON
Value
16#0000
16#0009
16#0000
16#A000
16#0000
16#0064
16#0000
16#A020
16#000A
16#0005
16#E001
16#0001
16#0000
16#0001

Advertisement