5.1 Testing

Power up the system
l
Program options as required (see programming section)
l
Trip then restore zones
l
Verify correct reporting codes are sent to the central monitoring station
l

5.2 Viewing Troubles from the Integrated Keypad

1. Move your hand over the iotega to illuminate the keypad.
2. Press * 2 .
3. Enter your access code if required. The Trouble LED on the keypad flashes if an access code is needed to view
troubles. Entering a valid access code silences trouble beeps.
4. The keypad displays top-level troubles present on the system by illuminating numbers on the keypad. Refer to the
table below for the meaning of each trouble code. When in the top level trouble display, the trouble LED flashes
once, pauses, then repeats.
5. If additional details are available for the trouble, the [*] key illuminates. Press any illuminated number to display the
second level troubles.
6. The keypad displays a second level of detail for the trouble code selected in step 5 by illuminating numbers on the
keypad. Refer to the table below for the meaning of each trouble code. When in the second level trouble display, the
trouble LED flashes two times, pauses, then repeats.
7. If additional details are available for the trouble, the [*] key illuminates. Press any illuminated number to display the
third level trouble detail.
8. The keypad displays the device number with the trouble condition. If more than one device has this trouble at the
same time, the keypad cycles though each one. When in the third level trouble display, the trouble LED flashes three
times, pauses, then repeats.
9. Press the [*] key to acknowledge a trouble.
Note: Pressing the # key returns you to the previous level. Pressing the # key while in the top-level exits the trouble menu.
Trouble Summary
Trouble [01] - System Trouble
l
Trouble [02] - Zone
l
Trouble [03] - Siren
l
Trouble [04] - Keypad
l
Trouble [05] - Repeater
l
Trouble [06] - Wireless Key
l
Trouble [07] - Communication
l
Trouble [00] - Integrator Trouble
l
Table 6-1
Trouble Indications
1 st Layer
01
System Trouble
02
Zone

Section 5: Troubleshooting

Section 5: Troubleshooting
2 nd Layer
01
AC
02
Battery Trouble
03
Tamper
04
Hardware Fault
05
Loss of Time
06
RF Jam
01
Future Use
02
Battery Trouble
03
Tamper
04
Fault (Supervision)
05
Not Networked
- 46 -
3 rd Layer
1-128
1-128
1-128
1-128