Zone Type
This programming section is used to program a zone type
for the device.
Default: Interior Follower
Valid
Instant, Interior Follower, Interior Stay/Away, Delay Stay/Away, 24
range:
Hour Supervisory Buzzer, 24 Hour Non Alarm
Device Label
This section is used to program a custom label for the
device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 43 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
4.7.6 Wireless Temperature Con-
figuration Options
The following sections are used for programming wireless
temperature sensors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Section 4: Programming Options
Enabled
Enabled
Enabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Disabled
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default:
Valid range:
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Valid range:
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 43 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Valid range:
Temperature Format
This section is used to select the scale temperature is dis-
played in.
Default:
F
Valid range:
F (Fahrenheit), C (Celsius)
- 35 -
Enabled
1-4
24-hour Temperature
24-hour Temperature
Zone ZZZ
32 character ASCII
Disabled
Enabled
Disabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Enabled
Enabled/Disabled