4.6 Partition Configuration
Options
This section describes programming options used to con-
figure individual partitions.
Partition Label
This option is used to add a unique label to each partition on
the system. This label is displayed on partition keypads and
event messages.
Default:
Blank
Valid range:
32 character ASCII
Partition Account Number
This option is used to add a unique account number to a par-
tition. When using formats other than SIA, the account num-
ber identifies the alarm system to the central monitoring
station when communicating partition-specific events.
Note: The iotega will not communicate if the account num-
ber is not programmed.
Default:
FFFF
Valid range:
0001 to FFFF (FFFF to disable communication)
Entry Delay 1
This value determines the entry delay time for Delay 1 type
zones.
Default:
30 seconds.
Valid range:
0 to 255 (standard)
30 to 255 Seconds (CP-01)
Entry Delay 2
This value determines the entry delay time for Delay 2 type
zones.
Default:
45 seconds (standard)
30 seconds CP-01
Valid range:
0 to 255 (standard)
30 to 255 Seconds (CP-01)
Exit Delay
This value determines the length of time given to exit the
premises before the system becomes fully armed.
During exit delay, the Ready LED illuminates. When the exit
delay expires, the Ready LED turns off and the Armed LED
illuminates.
Default:
60 seconds (CP-01).
Valid range:
45 to 255 (CP-01)
Section 4: Programming Options
004
000 to 255
Closing Delinquency Delay
This value determines the time the alarm system delays
before transmitting a close delinquency event to the central
monitoring station.
Default:
Valid range:
Cross Zone Delay
If another zone with the Burglary Verification attribute
enabled is violated within the duration of this timer, a Burg-
lary Verified event is communicated and logged.
Default:
Valid range:
Quick Arm
When this option is enabled, the iotega can be armed
without entering an access code.
Note: Quick arming cannot be initiated from the integrated
keypad.
Default:
Valid range:
Quick Exit
When this option is enabled, users can temporarily bypass a
Delay 1 or Delay 2 zone to exit the premises when the sys-
tem is armed. Only one delay zone may be activated. Activity
on another delay zone initiates the appropriate alarm
sequence. If the delay zone is still open two minutes after
being bypassed, entry delay is initiated. If armed in Stay
mode, the automatic bypass on Stay/Away zones remains.
Note: Quick Exit cannot be initiated from the integrated
keypad.
Default:
Valid range:
Internal Siren
When this option is enabled, The iotega's built-in siren activ-
ates during an alarm.
Default:
Valid range:
Internal Buzzer
When this option is enabled, the iotega's built-in buzzer
provides auditory feedback (e.g., key presses, door chime).
Default:
Valid range:
Auto Arm
When this option is enabled, the iotega automatically arms
in away mode (stay/away zones active) at a programmed
time each day. The keypad emits three beeps to indicate the
- 30 -
30 Days
0 to 255 Days
0 Seconds
0 to 255 Seconds
Enabled
Enabled/Disabled
Disabled
Enabled/Disabled
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled