Panic
To use the Emergency keys:
1. Press the Shift key (↑). The Emergency keys are illuminated (if enabled ). If an Emergency key is not pressed within
10 seconds, the keypad returns to normal operating mode.
2. Press and hold an Emergency key for 2 seconds to activate the alarm.

3.1.3 WPS Mode ([*][8])

WPS (WiFi Protected Setup) mode activates iotega's WiFi access point to facilitate connection with IP devices, such as the
touchscreen keypad and IP cameras.
To enable WPS mode:
1. At the installation site, tap [*] 8 on the integrated kaypad.
2. Enter a valid installer code. The WiFi signal strength LED flashes for two minutes to indicate the system is in WPS
mode.
The WPS window expires after 2 minutes.

3.1.4 Local Webpage ([*][8])

This mode is used to connect the iotega to the local WiFi router, configure static/dynamic ip address, configure WiFi settings
and to view panel, cellular status/information and firmware versions.
Note: WLAN Client Mode and Access Point must be enabled to use this feature.
The access window expires after 10 minutes.
To enable Local Webpage mode:
1. At the installation site, tap [*] 8 on the integrated kaypad.
2. Enter a valid installer code. The WiFi signal strength LED flashes for two minutes to indicate the system is in local
webpage mode.
To access the local webpage:
1. On your local device (mobile/laptop), locate the Guest AP network and join.
2. Enter your password (installer code twice. e.g., 55555555).
3. Use a web browser to access http://iotega.
Note: The access window timer can be restarted by pressing [*][8][installer code] again.

3.2 Arming and Disarming Methods

This section describes the arming methods available on the iotega.

3.2.1 Away Arming

Away Arming arms the entire system, including the perimeter and interior devices. The Ready light must be on to arm the
system. If the Ready light is off, ensure all protected doors and windows are secure or bypassed.
To arm the system, enter a valid access code. To disarm, enter a valid access code.
During exit delay, the Armed and Ready indicators turn on and the keypad beeps once every second during the exit delay
(and three times a second during the last 10 seconds) to alert the user to leave via a delay zone. The Ready light turns off
when the Exit Delay ends.
When the exit delay has expired, the system is armed as indicated by the following conditions:
the Ready indicator turns off.
l
the Armed indicator stays on.
l
the panel is silent.
l
Note: In Away Arming mode, bypassed zones are logged and communicated to the central monitoring station.

3.2.2 Stay Arming

Note: Requires at least one zone defined as Interior Stay/Away or Delay Stay/Away for this function to work.
Section 3: Operation
Keypad beeps three times and a signal is sent to the monitoring station.
Can be configured as audible or silent