system is armed. All arming inhibit features such as latching
tampers, AC inhibit, etc. also inhibit Auto Arming and send
the Auto Arm Cancellation code.
Default:
Disabled
Valid range:
Enabled/Disabled
Auto Arming by Schedule
This option is used to program the time of day each alarm
system partition automatically arms (in Away mode only). To
program an auto-arm time, select a day of the week and
then enter the time. At the programmed time, the keypad
buzzers beep to warn that automatic arming is in progress.
The siren also squawks once every 10 seconds during this
warning period if programmed to do so. When the warning
period is complete, the exit delay elapses and the system
arms in away mode.
Default:
0000
Valid range:
0000 to 2359 (4-Digit HH:MM) for each day of the week
Auto Arm Postpone Timer (for schedule only)
This option is used to program a time delay before the Auto
Arm sequence begins. Programming 0 cancels auto arming.
Default:
Valid range:
No Activity Arm timer
This option is used to tell the iotega to arm in Away mode
when no zone activity is detected during the programmed
amount of time. The timer restarts when a Delay type zone is
restored.
Default:
0 Minutes (disables feature)
Valid range:
0 to 255 Minutes
Bell Delay Time
This option determines how long after a burglar alarm
occurs that the bell sounds. Fire alarms sound immediately,
regardless of bell delay time setting. If all commucunication
paths are in fault, bell delay is cleared and alarms sound
immediately.
Bell delay is also cleared if alarms occur on the following
zone types:
24-hour CO, Auto-verified fire zone, delayed or standard 24-
hour fire zone, [F] key, audible [P] key, 24-hour latching
tamper, or indoor/outdoor siren tamper.
Note: EU Entry Procedure takes priority over bell delay. If an
alarm occurs during entry delay when EU Entry Procedure is
enabled, the bell sounds immediately.
Default:
000
Valid range:
000 to 255 Minutes
Bell Delay Partition Mask
This option enables or disables the Bell Delay feature for
individual partitions. When the option is enabled, Bell Delay
is applied to the selected partition during alarm conditions.
Section 4: Programming Options
0 Minutes
0-255 minutes
When the option is disabled, Bell Delay is not applied. The
default setting is (Y): enabled.
Settle Delay
This timer enables a programmable, short duration bypass
of all zones on the partition when arming. It allows motion
detectors to restore when the system is armed to help pre-
vent false alarms.
The typical value for this timer is 5 seconds, but can be
increased if false alarms persist. Program 000 for no settle
delay. The settle delay duration is programmed in seconds.
Default:
Valid range:
High Traffic Shutdown
Activating this feature helps conserve battery power when
the system is disarmed by configuring a reporting timer.
When motion is detected, the device transmits an alarm to
the receiver and does not report any further events until the
timer expires. Any motion detected during the configured
period is reported once the timer expires. No Delay causes
the device to report an alarm each time the detector is
tripped.
Default: Not Active
Valid
Not Active, No Delay, 5 Second Delay, 15 Second Delay, 30 Second
range:
Delay, 1 Minute Delay, 5 Minute Delay, 10 Minute Delay, 20 Minute
Delay, 60 Minute Delay
4.7 Wireless Device Con-
figuration Options
This section describes programming options used to con-
figure supported wireless PowerG devices.
4.7.1 Wirefree Keypad Configuration
Options
The following sections describe programming options used
to configure the available wirefree keypad.
Keypad Label
This section is used to program a user-friendly name for the
keypad.
Default:
Valid range:
Keypad Partition Assignment
This section is used to program the partition that the wirefree
keypad is assigned to.
Default:
0 to 255
- 31 -
000
000 to 010 seconds
Blank
32 character ASCII
1
1-4, ALL

Advertisement

Table of Contents