This product has been tested and found in compliance with the following standards:
UL1023 Household Burglar-Alarm System Units
l
UL985 Household Fire Warning System Units
l
ULC-S545-02 Residential Fire Warning System Control Units
l
ORD-C1023-1974 Household Burglar-Alarm System Units
l
This product has also been tested and found in compliance with the ANSI/SIA CP-01-2014 Control Panel Standard –
Features for False Alarm Reduction.
This product is UL/ULC listed under the following categories:
UTOU/UTOUC Control Units and Accessories, Household System Type
l
NBSX/NBSXC Household Burglar Alarm System Units
l
AMTB Control Panels, SIA False Alarm Reduction
l
The product is labeled with the UL and ULC listing marks along with the SIA CP-01 compliance statement (Also Classified
in accordance with SIA-CP-01 Standard) as proof of compliance with the above mentioned standards. For further inform-
ation on this product's listings please also refer to the official listing guides published at the UL web site (www.ul.com)
under Certifications Section.
Important Notes for EN50131-1 Compliant Systems
The WS912-28 Control Panel with 3G7090E-EU cellular communicator has been certified by Telefication according to
EN50131-1:2006+A1:2009+ A2:2017, EN50131-3:2009, EN50131-4: 2008, EN50131-10: 2014, EN50131-6:2017 (Type
A) and EN50136-1:2012 (SP2,DP2) for Grade 2, Class II. For EN50131 compliant installations, with alarm control panels
WS912-28 only the intrusion portion of the alarm system may be activated.
Note: For EN50131 compliant installations, only the intrusion portion of the alarm system has been investigated. Fire Alarm
and Auxiliary (Medical) alarm functions were not included in the evaluation of this product under the requirements of the
above mentioned standards. The certified wirefree keypad HS2LCDWF8 (P/N WS9LCDWF8) shall be used in order to ini-
tiate the walk test mode for model WS912-28.
Additional features implemented for EN 50131 Grade 2:
Fire alarm and CO alarm annunciation
Auxiliary (medical) alarm annunciation
This device is suitable for use in systems with the following notification options.
A (use of two warning devices and ATS SP2 - internal Ethernet or add on Cellular module 3G7090-EU required)
B (use of self-powered warning device and ATS SP2 - internal Ethernet or add on Cellular module 3G7090-EU required)
C and F (use of ATS DP2 - internal Ethernet and add on Cellular module 3G7090-EU in back-up mode required)
E (use of self-powered warning device and optional ATS)
WS912-28 integrates an SPT that can be configured for ATS categories SP2 and DP2.
For ATS category SP2, the following communications paths can be selected as a single communication means:
Ethernet path, or
l
Wi-Fi path, or
l
Cellular path
l
Note: The Ethernet path and Wi-Fi path are working in tandem and only one of them can be active at any given time. When
the Ethernet cable is present the Wi-Fi connection is disabled. When the Ethernet cable is removed the Wi-Fi connection is
enabled.
For ATS category DP2 the Ethernet path is the primary alarm transmission path and the Cellular path is the back-up chan-
nel. For this configuration in the dealer portal set the Ethernet and Cellular supervision interval to 850 sec (this will allow for
3 heartbeats in the 30 minute time frame). This can be found in the Communications Configuration tab.
The compatible SG-System I/II/III/IV/5 Alarm receiver shall have the option [113] set to 1800 (transmitter fail time) and option
[115] set to 900 (transmitter restore - since the device is set to a heartbeat every 850 this will speed up the restore from a
failed condition).
Appendix 3: Regulatory Information
Appendix 3: Regulatory Information
- 58 -