Other Communicator Related Options; Ethernet-Test-Transmission - DSC iotega WS910 Reference Manual

Wireless security and automation system
Table of Contents

Advertisement

Note: A cellular account code is necessary in order for the
iotega to communicate to the central monitoring station (if
cellular communication path is selected).
Default:
0000000000
Valid range:
0000000000 to FFFFFFFFFF
CMS Cellular 2 DNIS
The DNIS is used in addition to the account code to identify
the communicator module at the central monitoring station.
Default:
000000
Valid range:
000000 to 0FFFFF (first digit not used)
CMS Cellular 2 IP Address
Enter the Cellular receiver 2 IP address. This IP address will
be provided by the central monitoring station.
Note: When a valid address has been entered, Cellular
Receiver 2 is enabled and will communicate events over the
cellular path.
Default:
000.000.000.000
Valid range:
000.000.000.000.to 255.255.255.255
CMS Cellular 2 Remote Port
Enter the cellular receiver 2 IP address. This IP address will
be provided by the central monitoring station.
Note: When a valid address has been entered, cellular
receiver 2 is enabled and will communicate events over the
cellular path.
Default:
Valid range:
CMS Cellular 2 APN
The APN determines the cellular network that the com-
municator will connect to. This information is available from
the network carrier.
Note: When a SIM card with a custom APN is used, the unit
will not have access to the Internet. DLS and remote flash
can still be done if this option is programmed with a valid
public APN.
Default:
Blank
Valid range:
32 characters ASCII
CMS Cellular 2 Domain Name
This information is provided by the central monitoring station
system administrator.
Default:
Blank
Valid range:
32 characters ASCII
Section 4: Programming Options
3061 (0BF5)
0000 to 65535
4.3.1 Other Communicator Related
Options
Alternate Test Transmission
When this option is enabled, the test transmission alternates
between primary and secondary receivers with each test
transmission interval.
When disabled, the test transmission is sent to the pro-
grammed receivers, based on the settings of the periodic
test transmission reporting codes.
Default:
Valid range:

4.4 Ethernet-Test-Transmission

Ethernet Test Transmission
Enter a 6-digit number (000000-999999) to program
Enter a 4-digit number (0000-2359) using the 24-hour clock
format (HHMM) to set the time of day an Ethernet test trans-
mission is sent. Programming a value of 9999 disables the
test transmission time.
Note: The internal date and time is automatically pro-
grammed when the unit communicates with the primary
receiver.
Default:
9999
Valid range:
0000 to 2359, 9999 to disable
Ethernet Test Transmission Cycle
This option is used to program how often, in minutes, Eth-
ernet test transmissions are sent. Once the initial test trans-
mission is sent, all future test transmissions are offset by the
programmed number of days.
Default:
0 minutes.
Valid range:
000000 (disabled) to 999999 minutes.
Note: Programming an interval of less than 5 minutes or a
value greater than 999999 disables the test transmission.
Cellular Test Transmission Time
Enter a 4-digit number (0000-2359) using the 24-hour clock
format (HHMM) to set the time of day a cellular test trans-
mission is sent. Programming a value of 9999 disables the
test transmission time.
Note: The internal date and time will automatically be pro-
grammed when the unit communicates with the primary
receiver.
Default:
9999
Valid range:
0000 to 2359, 9999 to disable
Cellular Test Transmission Cycle
This option is used to program how often, in minutes, cel-
lular test transmissions are sent. Once the initial test
- 28 -
Enabled
Enabled/Disabled