communicated unless the siren has been active for at least
30 seconds.
Police code is not generated as a result of alarms triggered
during entry delay, although the Burglary Verification Timer
starts after entry delay and the 30-second communication
delay expire.
This feature is only active when the partition is armed.
When this option is disabled, burglary alarms that occur dur-
ing entry delay activate the siren and are communicated
immediately. Two exceptions are if the bell delay timer is pro-
grammed and if transmission delay is enabled for the zone
in alarm. In both cases, the alarm follows the timer.
Default:
Disabled
Valid range:
Enabled/Disabled
Troubles Inhibit Arming
When this option is enabled, the following troubles prevent
arming until restored:
Tampers on the system, modules and zones
l
AC troubles on the system and modules
l
Battery troubles on the system and zones
l
Transmission troubles (FTC, GPRS, Ethernet)
l
The alarm system can still be armed if troubles are over-
ridden. To perform a trouble override, while in the Trouble
Menu ([*][2]), scroll right or left and press [*] when Trouble
Acknowledgment is displayed on the keypad. Alternatively,
press the [9] key to acknowledge and override the existing
troubles.
To override open zones, faulted zones or tampered zones,
use the Zone Bypass feature.
Note: When this option is disabled, the system can be
armed even when troubles are present.
Note: When Engineer's Reset is on, trouble conditions can-
not be overridden. Zone Expander supervisory troubles can-
not be acknowledged and overridden. These conditions
must be restored before the panel can be armed.
Default:
Disabled
Valid range:
Enabled/Disabled
Open Zones Cancel Arming
When this option is enabled, the system cannot be armed
while zones are open unless a valid access code is entered.
In order to bypass open zones, the bypass attribute must be
enabled for the zone.
When this option is disabled, open zones do not prevent
arming.
Default:
Enabled
Valid range:
Enabled/Disabled
Engineer's Reset (EU)
When this option is enabled, if the system has gone into
alarm during the previous armed period, or if a 24-hour
alarm has occurred (armed or disarmed), the system cannot
be armed (Ready light OFF) until Installer Programming is
Section 4: Programming Options
entered or Engineer's Reset is performed via DLS. "Reset
Required" is displayed on the keypad. This feature also
applies to tampers and faults in both armed and disarmed
states and does not apply to module tampers, system super-
visory alarms, zone expander alarms.
Note: If Engineer's Reset is triggered during exit delay, the
system still arms. Troubles cannot be overridden while
Engineer's Reset is enabled.
When this option is disabled, the system does not require
Engineer's Reset or to be placed into Installer Programming
in order to arm the system after an alarm.
Default:
Valid range:
Tamper/Fault Detection
When this option is enabled, the following trouble con-
ditions, when configured to generate audible alarm con-
ditions, contribute to a burglary verification sequence when
sequential detection is used. Bell circuit trouble also gen-
erates an audible alarm condition using other sirens
assigned to the partition.
Bell circuit trouble
l
Zone fault
l
Module supervisory trouble
l
Alternate Communicator fault
l
Ethernet Trouble
l
When this option is disabled, trouble conditions are dis-
played and processed as per standard operation.
Default:
Valid range:
EU Sequential Detection
This option is enabled by setting Burglary Verification Selec-
tion to Sequential Detection. Sequential detection is used in
applications where various trouble conditions, classified as
sabotage conditions, can contribute to a confirmed alarm
condition. The burglary verification timer is in minutes.
The features related to this operation are:
Burglary Verification Zone Attribute
l
Transmission Delay Zone Attribute
l
Burglary Verification Counter
l
Burglary Verification Selection
l
Burglary Verification Timer
l
Transmission Delay
l
This feature is meant for use with the EU entry procedure
instead of the normal Police Code or Cross Zoning features.
For Europe, sabotage (tamper) events must contribute to a
verified burglary alarm and the bell must activate for all
alarm conditions.
Default:
Valid range:
- 19 -
Disabled
Enabled/Disabled
Disabled
Enabled/Disabled
Enabled
Enabled/Disabled