The following tables contain Contact ID and Automatic SIA format reporting codes.
Contact ID
Each of the digits indicate specific information about the signal. For example, if zone 1 is an entry/exit point, the event code
contains [34]. The central monitoring station would receive the following:
*BURG - ENTRY/EXIT - 1 where the "1" indicates which zone went into alarm.
see "Contact ID and SIA Zone Alarm/Restore Event Codes" on page 52 for code definitions.
SIA Format - Level 2 (Hard Coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication
Standard - October 1997. This format sends the account code along with its data transmission. The transmission appears
similar to the following at the receiver:
N ri1 BA 01
N = New Event
ri1 = Partition /Area Identifier
BA = Burglary Alarm
01 = Zone 1
A system event uses the Area Identifier ri00.
Contact ID and SIA Zone Alarm/Restore Event Codes
Section #
Definition
Zone Events
Zone Alarms
Zone Restores
Zone tamper/restore
Zone fault/restore
Tamper Events
Keypad 1 tamper/restore alarm
Keypad 2 tamper/restore alarm
Keypad 3 tamper/restore alarm
Keypad 4 tamper/restore alarm
Siren 1 tamper/restore alarm
Siren 2 tamper/restore alarm
Siren 3 tamper/restore alarm
Siren 4 tamper/restore alarm
Siren 5 tamper/restore alarm
Siren 6 tamper/restore alarm
Siren 7 tamper/restore alarm
Siren 8 tamper/restore alarm
Siren 9 tamper/restore alarm
Siren 10 tamper/restore alarm
Siren 11 tamper/restore alarm
Siren 12 tamper/restore alarm
Siren 13 tamper/restore alarm
Siren 14 tamper/restore alarm
Siren 15 tamper/restore alarm
Siren 16 tamper/restore alarm
Repeater 1 tamper/restore alarm
Repeater 2 tamper/restore alarm
Repeater 3 tamper/restore alarm
Repeater 4 tamper/restore alarm
Repeater 5 tamper/restore alarm
Repeater 6 tamper/restore alarm
Appendix 2: Reporting Codes
Appendix 2: Reporting Codes
- 52 -
Dialer Dir-
Automatic Contact ID
ection*
Codes
A/R
see "Contact ID & SIA Zone Alarm/Restore Event Codes" on
page 55" for details.
A/R
MA/R
E(3)83-ZZZ / R(3)83-ZZZ
MA/R
E(3)8A-ZZZ / R(3)8A-ZZZ
T/R
E(3)83-601 / R(3)83-601
T/R
E(3)83-602 / R(3)83-602
T/R
E(3)83-603 / R(3)83-603
T/R
E(3)83-604 / R(3)83-604
T/R
E (3)83-801 / R (3)83-801
T/R
E(3)83-802 / R (3)83-802
T/R
E(3)83-803 / R (3)83-803
T/R
E (3)83-804 / R (3)83-804
T/R
E(3)83-805 / R (3)83-805
T/R
E(3)83-806 / R (3)83-806
T/R
E(3)83-807 / R (3)83-807
T/R
E(3)83-808 / R (3)83-808
T/R
E(3)83-809 / R (3)83-809
T/R
E (3)83-810 / R (3)83-810
T/R
E(3)83-811 / R (3)83-811
T/R
E (3)83-812 / R (3)83-812
T/R
E(3)83-813 / R (3)83-813
T/R
E (3)83-814 / R (3)83-814
T/R
E(3)83-815 / R (3)83-815
T/R
E (3)83-816 / R (3)83-816
T/R
E(3)83-901 / R (3)83-901
T/R
E(3)83-902 / R (3)83-902
T/R
E(3)83-903 / R (3)83-903
T/R
E(3)83-904 / R (3)83-904
T/R
E(3)83-905 / R (3)83-905
T/R
E(3)83-906 / R (3)83-906
SIA Auto Rep Codes**
TA-ZZZ / TR-ZZZZ
UT-ZZZZ / UJ-ZZZZ
TA-0601 / TR-0601
TA-0602 / TR-0602
TA-0603 / TR-0603
TA-0604 / TR-0604
TA-0801 / TR-0801
TA-0802 / TR-0802
TA-0803 / TR-0803
TA-0804 / TR-0804
TA-0805 / TR-0805
TA-0806 / TR-0806
TA-0807 / TR-0807
TA-0808 / TR-0808
TA-0809 / TR-0809
TA-0810 / TR-0810
TA-0811 / TR-0811
TA-0812 / TR-0812
TA-0813 / TR-0813
TA-0814 / TR-0814
TA-0815 / TR-0815
TA-0816 / TR-0816
TA-0901 / TR-0901
TA-0902 / TR-0902
TA-0903 / TR-0903
TA-0904 / TR-0904
TA-0905 / TR-0905
TA-0906 / TR-0906

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iotega ws912

Table of Contents