DSC iotega WS910 Reference Manual page 21

Wireless security and automation system
Table of Contents

Advertisement

troubles through the keypad buzzer every 10 seconds.
Pressing any key on the keypad silences the trouble beeps;
however, new troubles will restart trouble beeps. For
troubles that have been silenced but are still present, trouble
beeps restart daily at 7AM.
Default:
Enabled
Valid range:
Enabled, Disabled
Burglary Bell Time-out
This option determines the length of time the system siren
sounds for. System tampers follow this timer, but Fire alarms
and keypad buzzers do not.
Default:
Valid range:
Fire Bell Time-Out
This option determines the maximum activation time for fire
alarm sirens. Each partition has a dedicated Fire Bell Time-
out timer.
Fire Bell Time-out takes priority over Burglary Bell Time-out.
Default:
Valid range:
Audible Wireless Device Fault
When this option is enabled and the system is armed, wire-
less zone faults cause the siren to sound. The following
zone types do not generate an alarm when in fault during
stay arm mode: interior stay away zone, delay stay away
zone, instant stay away zone, night zone. The following
zone types do not generate an audible alarm in any armed
mode (stay, away, or night): 24-hour supervisory, 24-hour
non-alarm, 24-hour CO, delayed 24-hour Fire, standard 24-
hour fire, Auto-verified fire.
When the partition is armed, wireless supervisory troubles
from sirens, keypads and repeaters generate audible alarm
conditions.
If Tamper/Fault Detection is enabled, these events start the
burglary verified timer and affect the burglary verified
counter.
OFF: Wireless zone faults do not sound the siren.
Default:
Disabled
Valid range:
Enabled/Disabled
Audible Panic
This option is used to set internal buzzer behavior when the
Panic key is pressed. When set to Audible, pressing the
Panic key causes the buzzer to sound a series of 3 beeps to
acknowledge the alarm. The buzzer then sounds a steady
tone for the length of the bell time-out or until an access
code is entered.
When set to Silent, pressing the Panic key causes the
buzzer and the bell output to remain silent, but the alarm is
still transmitted (if programmed).
Section 4: Programming Options
4 Minutes
0 to 255 Minutes
5 Minutes
0 to 255 Minutes
Default:
Valid range:
Remote Reset
When this option is enabled, if an alarm occurs on a burg-
lary zone, the system is locked out after disarming. It
remains locked until a 5-digit reset code, provided by the
installer/central station, is keyed in. If a duress code is used
to disarm the partition, the system is not locked out.
In the disarmed state, only Audible 24 Hour Burglary zones,
Audible 24 Hour Latching Tamper zones, and Audible 24
Hour zone cause lockout.
To obtain the reset code, the user must provide a cor-
responding system lock code, displayed on the keypad
when one of the following conditions occurs:
the system has been disarmed (Duress Code
l
excluded)
the bell has timed out (24Hr zones)
l
an access code has been entered (24Hr zones)
l
On an LCD keypad, the message "REMOTE RESET RQD" is
displayed on the top line and "CODE" along with the actual
code is displayed across the bottom line.
On an LED keypad, the reset number is scrolled across the
screen.
While the system is locked out, only [*][3], [*][6], [*][7], and [*]
[8] are available. Accessing [*][8] Installer Programming
unlocks the alarm system. The system continues to function
(alarms, tampers, etc) while the system is locked out. Lock-
out follows both transmission and bell delays.
When this option is disabled, the system is not locked out
after an alarm occurs.
Note: EU Entry Procedure takes priority over bell delay. If an
alarm occurs during entry delay when EU Entry Procedure is
enabled, the bell sounds immediately.
Default:
Valid range:
Remote Reset Follows Sequential Detection
When this option is enabled, remote reset is only required
after disarming if a sequential detection alarm was gen-
erated and logged in the previous armed state.
When disabled, any burglary alarm requires remote reset
after disarming the partition.
Default:
Valid range:
EU Entry Procedure
When this option is enabled, if an alarm occurs on a zone
when entry delay is not active, the siren activates and the
alarm is communicated immediately, depending on the zone
type tripped.
When entry delay is active, all burglary type alarms activate
the siren, but communication of the alarm is delayed by 30
seconds. When entry delay expires, the alarm is not
- 18 -
Silent
Audible, Silent
Enabled
Enabled/Disabled
Disabled
Enabled/Disabled