2-Way Voice Options - DSC iotega WS910 Reference Manual

Wireless security and automation system
Table of Contents

Advertisement

transmission is sent, all future test transmissions are offset
by the programmed number of minutes.
Default:
0 minutes.
Valid range:
000000 to 999999 minutes
Note: Programming an interval of less than 5 minutes or a
value greater than 999999 disables the test transmission.
Commercial Supervision
When this option is enabled, swap detection is provided on
the supervisory packet. When disabled, only supervision of
the communicator path to the receiver is provided.
Default:
Enabled
Valid range:
Enabled/Disabled
Ethernet Supervision Interval (Heartbeat)
This option is used to set the frequency (in seconds) when
supervisory heartbeats are sent to the Ethernet receiver. If
the programmed value is 000 seconds, supervision is dis-
abled.
Note: Commercial Supervision must be enabled in order to
test the communications path.
Default:
000
Valid range:
001 to 255 Seconds, 000 to Disable
Cellular Supervision Interval ( Heartbeat)
This option is used to set the frequency (in seconds) when
supervisory heartbeats are sent to the cellular receiver. If the
programmed value is 000 seconds, supervision is disabled.
Note: Commercial Supervision must be enabled in order to
test the communications path.
Default:
000
Valid range:
001 to 255 Seconds, 000 to Disable
CMS Event Heartbeat Interval
This option is used to program the periodic heartbeat inter-
val between the alarm panel and the cellular communicator.
The heartbeat is used to monitor for image/audio file
requests.
Default:
15 Seconds, 0 to disable
Valid range:
000 to 255 Seconds
Communication Trouble Delay Time
This option is used to program the amount of time before the
following troubles are transmitted to the central monitoring
station:
Ethernet trouble
l
Cellular trouble
l
Supervision trouble
l
WIFI trouble
l
Default:
000
Valid range:
000 to 254 seconds, 000=Instant, 255=Disabled
Section 4: Programming Options
Visual Verification
This feature enables the central monitoring station operator
to view images captured via installed camera/motion detect-
ors during an alarm.
Visual verification sessions are triggered by the following:
Fire key
l
Medical key
l
Panic key
l
Alarms detected by armed PIR cameras
l
Note: The microphone on the camera PIR can be disabled.
Default:
Valid range:
Video on Demand
When this option is enabled, the central monitoring station
can request a video image file from an installed cam-
era/motion detector within 60 minutes of an alarm.
Default:
Valid range:
Firmware update Over Cellular
Default: Disabled
Valid range: Enabled, Disabled
Enabled: Installers can perform remote firmware updates via
cellular radio.
Disabled: Firmware updates cannot be performed via cel-
lular radio.

4.5 2-Way Voice Options

Alternate Phone Number
This section is used to program the SIM phone number.
Default:
Valid range:
Two Way Voice
When this option is enabled, Talk/Listen-in capability for
audio verification of alarms is available.
Default:
Valid range:
Microphone Gain
This section is used to program the volume level of the built-
in microphone. 001 is the lowest volume level. 000 disables
the microphone.
Default:
Valid range:
Voice Volume
This option is used to program the volume level of the built-
in speaker. 000 disables the speaker.
- 29 -
Enabled
Enabled/Disabled
Enabled
Enabled/Disabled
Blank or Auto-populated
32-Digit Phone Number
Disabled
Enabled/Disabled
001
000 to 255