Default:
Valid range:
[P] Key Alarm Control (for 2-way Voice) - Read Only
When this option is enabled, a 2-way talk/listen-in session is
initiated when the Panic [P] key is tapped. Note that the [P]
key must be programmed as audible in order to initiate 2-
way audio. If the [P] key is programmed as silent, a listen-in
only session is initiated when the Panic [P] key is tapped.
Default:
Valid range:
Duress Alarm Control ( for 2-way Voice) - Read Only
When this option is enabled, a Listen-in session is initiated
when a Duress alarm occurs.
Default:
Valid range:
Wireless Siren Control During 2-way Voice
When this option is enabled and an audible alarm is
present, the wireless siren activates during a 2-way audio
session.
When disabled, the wireless siren is silent when a 2-way
audio session begins. This allows the user to better hear the
operator. The sounder resumes operation for the timeout dur-
ation if the panel has not been disarmed at the end of the 2-
way session.
Default:
Enabled
Valid range:
Enabled, Disabled
New Alarms Disconnect 2-Way Audio
When this option is enabled, a listen in/2-way audio session
in progress is disconnected in favor of the incoming alarm.
This option is useful when using a 2G network, as voice (2-
way audio) and data (alarm) sessions cannot take place at
the same time.
Note: Fire/CO alarms override this option and force a dis-
connect (if necessary) in order to communicate the event.
When this option is disabled, new alarms do not disconnect
2-way audio. If a new alarm is generated during the first 70
seconds of the two-way voice interval, the monitoring station
operator has 20 seconds to begin another two-way voice
interval.
If the new alarm is generated during the last 20 seconds of
the two-way voice interval, the monitoring station operator
has the remainder of the interval to begin another two-way
voice interval.
Default:
Disabled
Valid range:
Enabled/Disabled
12/24 Hour Clock
When this option is enabled, time is displayed in 24-hour
clock format.
Section 4: Programming Options
Enabled
Enabled
Enabled
Enable
Enabled
Enabled
- 22 -
Default:
Enabled
Valid range:
Enabled/Disabled

4.2.1 Reporting Configuration Options

Open/Close
When this option is enabled, the following open/close
events are reported to the central monitoring station when
they occur. When disabled, open/close events are not repor-
ted.
Away Arming (Close)
l
Stay Arming (Close)
l
Disarm (Open)
l
Special Closing
l
Auto Arming
l
No Activity Arming
l
Auto Arm Cancel Postponed
l
Default:
Enabled
Valid range:
Enabled/Disabled
Special Alarm Comms
When this option is enabled, the following special alarm
events are reported to the central monitoring station when
they occur. When disabled, special alarm events are not
reported.
Exit Error
l
Recent Closing
l
Local keypad Lockout
l
Remote Lockout
l
Default:
Enabled
Valid range:
Enabled/Disabled
Maintenance
When this option is enabled, the following maintenance
events are reported to the central monitoring station when
they occur. When disabled, maintenance events are not
reported.
Event Buffer Full
l
Close Delinquency
l
Cold Start
l
Installer Lead In/Out
l
FW Update( Begin, Successful, Fail)
l
Default:
Enabled
Valid range:
Enabled/Disabled
System-Wide Troubles
When this option is enabled, the following system trouble
events are reported to the central monitoring station when
they occur. When disabled, system trouble events are not
reported.
AC Loss and restore
l
Battery trouble and restore
l
Tamper and restore
l
Hardware fault and restore
l
RF Jam trouble and restore
l