Wireless Smoke And Co Configuration Options; Wireless Glassbreak Configuration Options - DSC iotega WS910 Reference Manual

Wireless security and automation system
Table of Contents

Advertisement

**Not applicable for PGx938 and PGx949.
Supervision
This option is used to control battery supervision of the wire-
less key. When enabled, the iotega detects and reports a
wireless key low battery condition.
This feature is only applicable for PGx938.
Default:
Disabled (Must be enabled for UL)
Valid range:
Enabled/Disabled
User ID
All wireless keys are assigned to the Master user by default.
Assignment to another user is done via the touchscreen
keypad. Assigning wireless keys to specific users aids in
tracking and logging system events.
Not applicable for PGx938
Default:
Valid range:
4.7.4 Wireless Smoke and CO Con-
figuration Options
The following sections are used for programming wireless
smoke and CO detectors.
Device Enable/Disable
This option is used to enable and disable wireless smoke
and CO detectors.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to assign wireless smoke and CO detect-
ors to an available partition.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This programming option is used to program a zone type for
the device.
Default:
24-hour standard fire
Valid range:
24-hour standard fire, Auto-verified fire
Device Label
This section is used to program a custom label for the
device.
Section 4: Programming Options
None
001-100
1
1-4
- 34 -
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 43 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This section is used to enable/disable wireless supervision
of the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled (Must be enabled for UL)
Valid range:
Enabled/Disabled
4.7.5 Wireless Glassbreak Con-
figuration Options
The following sections are used for programming glass-
break detectors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Device Partition Assignment
This option is used to assign the wireless device to an avail-
able partition.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Disabled
Enabled
Disabled (read-only)
Disabled (read-only)
Enabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
Disabled (read-only)
1