Repeater Configuration Options - DSC iotega WS910 Reference Manual

Wireless security and automation system
Table of Contents

Advertisement

Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default:
Valid range:
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Type
This option is used to program a zone type for the device.
Default:
Instant (Perimeter)
Valid range:
24 Hour Burglary, Day Zone, Instant (Perimeter)
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 43 for attribute
definitions.
Door Chime
Alarm Report
Burglary Verified
Transmission Delay
Bell Audible
Bell Steady
Bypass Enable
Force Arm
Swinger Shutdown
Two Way Audio
Talk Listen
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
Alarm LED
This option is used to enable/disable the device's onboard
LED. When enabled, the LED activates when an alarm
occurs.
Section 4: Programming Options
Enabled
1-4
Enabled
Enabled
Enabled
Enabled
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Disabled (read-only)
Enabled (read-only)
Enabled (read-only)
Enabled (read-only)
Default:
Valid range:
Reed Switch
This option is used to enable/disable the device's built-in
reed switch. The reed switch is used in conjunction with the
separately mounted magnet as part of the trigger mech-
anism.
If the reed switch is enabled and a device is hardwired to the
external input terminals, both sensors transmit sim-
ultaniously. However, the iotega treats both devices as the
same zone. Disable the reed switch to have the hardwired
device funciton independantly.
Default:
Valid range:
Zone EOL Configuration
This option is used to configure end of line resistors for the
external input terminals. The alarm panel uses EOL resistors
to monitor for fault or alarm conditions.
Default:
EOL Disable
Valid range:
Single, EOL Disable, Normal Open, Normal Close
Shock Accumulation
Shock accumulation is used to count a series of low level
impacts that fall below the programmed alarm threshold
(see Shock Sensitivity) over a ten-second period.
If the total energy of the low level impacts surpasses the
threshold, an alarm is triggered. If not, the accumulation
level is reset.
Default:
Valid range:
Shock Sensitivity Level
This option is used to adjust the sensitivity of the sensor. The
lower the number, the more sensitive the device. Use the
lowest settings for hard surfaces such as concrete.
Default:
Valid range:

4.7.12 Repeater Configuration Options

The following sections are used to program wireless repeat-
ers.
Device Label
This section is used to program a custom label for the
device.
Default:
Valid range:
- 40 -
Enabled
Enabled/Disabled
Disabled
Enabled/Disabled
Enabled
Enabled/Disabled
8
1-19
Repeater X
32 character ASCII

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iotega ws912

Table of Contents