Parameter mode (code P)
Code
PA-01
Forced operation mode selection
PA-02
Forced operation frequency setting
Forced operation rotation direction
PA-03
command
Commercial power supply bypass
PA-04
function selection
PA-05
Bypass function delay time
Code
Name
Simulation mode
PA-20
selection
Selection of error code
PA-21
for alarm test
Output current monitor
PA-22
optional output selection
Output current monitor
PA-23
optional setting value
P-N voltage monitor
PA-24
optional output selection
P-N voltage monitor
PA-25
optional setting value
Output voltage monitor
PA-26
optional output selection
Output voltage monitor
PA-27
optional setting value
Output torque monitor
PA-28
optional output selection
Output torque monitor
PA-29
optional setting value
Frequency adjustment
PA-30
optional output selection
Frequency matching
PA-31
optional setting value
Name
00 (Disabled)/01 (Enabled)
0.00~590.00 (Hz)
00 (Normal rotation)/01 (Reverse rotation)
00 (Disabled)/01 (Enabled)
0.0~1000.0 (s)
00 (Disabled)/01 (Enabled)
000~255
00 (Disabled)/01 (Enabled: parameter setting [PA-23])
02 (Enabled: set from [Ai1])/03 (Enabled: set from [Ai2])/
04 (Enabled: set from [Ai3])/05 (Enabled: set from [Ai4])/
06 (Enabled: set from [Ai5])/07 (Enabled: set from [Ai6])
0.0 to 3.0 × Inverter rated current (A)
00 (Disabled)/01 (Enabled: parameter setting [PA-25])
02 (Enabled: set from [Ai1])/03 (Enabled: set from [Ai2])/
04 (Enabled: set from [Ai3])/05 (Enabled: set from [Ai4])/
06 (Enabled: set from [Ai5])/07 (Enabled: set from [Ai6])
200V class: 0.0 to 450.0 (Vdc)
400V class: 0.0 to 900.0 (Vdc)
00 (Disabled)/01 (Enabled: parameter setting [PA-27])
02 (Enabled: set from [Ai1])/03 (Enabled: set from [Ai2])/
04 (Enabled: set from [Ai3])/05 (Enabled: set from [Ai4])/
06 (Enabled: set from [Ai5])/07 (Enabled: set from [Ai6])
200V class: 0.0-300.0 (V)
400V class: 0.0-600.0 (V)
00 (Disabled)/01 (Enabled: parameter setting [PA-29])
02 (Enabled: set from [Ai1])/03 (Enabled: set from [Ai2])/
04 (Enabled: set from [Ai3])/05 (Enabled: set from [Ai4])/
06 (Enabled: set from [Ai5])/07 (Enabled: set from [Ai6])
-500.0~+500.0 (%)
00 (Disabled)/01 (Enabled: parameter setting [PA-31])
02 (Enabled: set from [Ai1])/03 (Enabled: set from [Ai2])/
04 (Enabled: set from [Ai3])/05 (Enabled: set from [Ai4])/
06 (Enabled: set from [Ai5])/07 (Enabled: set from [Ai6])
0.0~590.00 (Hz)
Appendix 1-61
Data range
Data range
List of Parameters
Initial value
Note
Page
00
0.00
12-17-13
00
00
12-17-15
5.0
Initial value
Note
Page
00
000
01
0.0
01
200 V class:
270.0
400V class:
540.0
10-9
01
0.0
01
0.0
01
0.00

Advertisement