Appendix 1
Code
bb-43
Restarting level of frequency acquisition
Constant (frequency) for frequency
bb-44
acquisition restarting
Constant (voltage) for frequency
bb-45
acquisition restarting
Overcurrent suppression level for
bb-46
frequency pull-in restart
Start frequency selection for frequency
bb-47
pull-in restart
bb160
First overcurrent detection level
bb-61
Excessive voltage of accepted power
bb-62
Incoming overvoltage level selection
bb-64
Ground fault detection selection
bb-65
Input phase loss selection
bb-66
Output phase loss selection
bb-67
Output phase loss detection sensitivity
bb-70
Thermistor error level
bb-80
Over-speed error detection level setting
bb-81
Over-speed error detection time
bb-82
Operation for speed deviation error
Speed deviation error detection level
bb-83
setting
bb-84
Speed deviation error detection time
Behavior when the position deviation is
bb-85
abnormal
Abnormal position deviation detection
bb-86
level
bb-87
Abnormal position deviation time
bb201
Second carrier frequency
bb202
Second sprinkle carrier pattern selection
Second automatic carrier frequency
bb203
reduction selection
bb260
Second overcurrent detection level
*1) P1-01760-H (P1-750H) to P1-03160-H (P1-1320H) shall
be as follows.
[Ub-03]=02: 0.5~10.0 (kHz)
[Ub-03]=00 or 01: 0.5~8.0 (kHz)
Name
(0.00 to 2.00)
× Inverter rated current (A)
0.10~30.00 (s)
0.10~30.00 (s)
(0.20 to 2.00)
× Inverter rated current (A)
00 (Cutoff frequency)/
01 (Maximum frequency)/
02 (Setting frequency)
(0.20 to 2.20)
x Inverter ND rated current
00 (Warning)/01 (Error)
(200V class) 300.0 - 410.0 (V)
(400V class) 600.0 - 820.0 (V)
00 (Disabled)/01 (Enabled)
00 (Disabled)/01 (Enabled)
00 (Disabled)/01 (Enabled)
1~100 (%)
0~10000 (Ω)
0.0~150.0 (%)
0.0~5.0 (s)
00 (Warning)/01 (Error)
0.0~100.0 (%)
0.0~5.0 (s)
00 (Warning)/01 (Error)
0.0~65535 (×100pls)
0.0~5.0 (s)
[Ub-03]=02: Normal duty
[Ub-03]=01: Low duty
[Ub-03]=00: Very low duty
*1)
00 (Disabled)/
01 (Pattern 1 enabled)/
02 (Pattern 2 enabled)/
03 (Pattern 3 enabled)/
00 (Disabled)/
01 (Enabled: current)/
02 (Enabled: temperature)
(0.20 to 2.20)
x Inverter ND rated current
Appendix 1-29
Data range
× Inverter ND
(200 V class) 390.0
(400V class) 780.0
0.5~16.0 (kHz)
0.5~12.0 (kHz)
0.5~10.0 (kHz)
List of Parameters
Initial value
Note
1.00
× Inverter
rated current
0.50
0.50
1.00
× Inverter
rated current
00
2.20
rated current
00
01
00
00
10
3000
135.0
0.5
00
15.0
0.5
00
4096
0.5
2.0
00
00
2.20
× Inverter
rated current
Page
12-14-6
12-14-6
12-14-6
12-14-6
12-14-6
12-16-5
18-15
12-16-1
12-16-2
12-16-2
12-16-12
12-16-12
12-16-11
12-16-11
12-16-11
12-17-18
12-17-18
12-17-18
12-17-1
12-17-1
12-17-1
12-17-1

Advertisement

Table of Contents
loading

Table of Contents