A1.4 List of Parameter Modes
Parameter mode (code A)
Code
Name
First main speed
AA101
command selection
First auxiliary speed
AA102
command selection
First auxiliary speed
AA104
setting
AA105
First operator selection
First additional
AA106
frequency setting
First operation
AA111
command selection
RUN key operation
AA-12
direction selection
AA-13
STOP key selection
First operation direction
AA114
limit selection
First stop mode
AA115
selection
AA121
First control mode
First vector control
AA123
mode selection
*1) Cannot be selected if [Ub-03] duty spec selection is 01
(LD) or 02 (VLD).
*2) Cannot be selected if [Ub-03] duty spec selection is 02
(VLD) or 02 (VLD).
Data range
01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Ai4 terminal input: P1-AG)/
05 (Ai5 terminal input: P1-AG)/06 (Ai6 terminal input: P1-AG)/
07 (Parameter setting)/08 (RS 485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)/12 (Pulse string input: main unit)/
13 (Pulse string input: P1-FB)/14 (Program function)/
15 (PID calculation)/16 (QOP-VR)
00 (Disabled)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Ai4 terminal input: P1-AG)/
05 (Ai5 terminal input: P1-AG)/06 (Ai6 terminal input: P1-AG)/
07 (Parameter setting)/08 (RS 485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)/12 (Pulse string input: main unit)/
13 (Pulse string input: P1-FB)/14 (Program function)/
15 (PID calculation)/16 (QOP-VR)
0.00~590.00 (Hz)
00 (Disabled)/01 (Addition)/02 (Subtraction)/03 (Multiplication)
-590.00~590.00 (Hz)
00 ([FW]/[RV] terminal)/01 (3 wire)/
02 (RUN key on operator keypad)/03 (RS485)/04 (Option 1)/
05 (Option 2)/06 (Option 3)
00 (Normal rotation)/01 (Reverse rotation)
00 (Disabled)/01 (Enabled)/02 (Only reset is enabled)
00 (No limitation)/01 (Only normal rotation)/
02 (Only reverse rotation)
00 (Deceleration stop)/01 (Free run stop)
00 ([V/f] Fixed torque characteristics (IM))/
01 ([V/f] Reducing torque characteristics (IM))/
02 ([V/f] Free V/f (IM))/03 ([V/f] Auto torque boost (IM))/
04 ([V/f with sensor] Fixed torque characteristics (IM)/
05 ([V/f with sensor] Reduced torque characteristics (IM)/
06 ([V/f with sensor] Free V/f (IM)/
07 ([V/f with sensor] Auto torque boost (IM)/
08 (Sensorless vector control (IM))/
09 (Zero-Hz range sensorless vector control (IM)) *1)/
10 (Vector control with sensor (IM)) *1)/
11 (Synchronous start type sensorless vector control
(SM/PMM))/
12 (IVMS start type sensorless vector control (SM/PMM)) *2)
00 (Speed/torque control mode)/
01 (Pulse string position control mode)/
02 (Absolute position control mode)/
03 (High-resolution absolute position control mode)
Appendix 1-8
List of Parameters
Initial value
Note
Page
07 (*FF)/
01 (*FEF,
*FUF,
*FCF)
00
0.00
00
0.00
02 (*FF)/
00 (*FEF,
*FUF,
*FCF)
00
01
00
00
12-15-1
00
12-9-1
00
12-9-16

Advertisement