Hitachi SJ Series User Manual page 194

Hide thumbs Also See for SJ Series:
Table of Contents

Advertisement

Chapter 12
12.5.8
Temporary change of operation
command destination
• Want to make operation from the operator keypad
temporarily.
• Want to make operation from the terminal block
input temporarily.
• When 023 [F-OP] terminal is ON, the command
destination of [CA-71] is employed in a priority to
the operation command destination given in
[AA111].
Parameters
Item
Input terminal function
selection
Frequency command
selection with [F-OP]
enabled.
Operation command
selection with [F-OP]
enabled.
Parameters
[CA-01]~[CA-11]
[CA-70]
[CA-71]
12-5-7
• When 023 [F-OP] terminal is ON, the frequency
command destination also employs the frequency
command selection designated in [CA-70].
• If [AA111] and [CA-71] are set differently from each
other, the operation is interrupted when the [F-OP]
terminal is made ON or OFF. The selected
operation command is enabled when it is made
OFF and then ON.
Data
023
[F-OP]: Gives a forced command.
01: Ai1-L input, 02: Ai2-L input, 03: Ai3-L input,
04: Ai4-L input, 05: Ai5-L input, 06: Ai6-L input,
07: parameter setting, 08: RS485
communication, 09:option 1, 10: option 2, 11:
01~15
option 3, 12: pulse string input (main body), 13:
pulse string input (optional) 14: program
function EzSQ, 15: PID
00: [FW]/[RV] terminal, 01: 3 wire, 02: RUN key
on operator keypad, 03: RS485
00~06
communication, 04: option 1, 05: option 2, 06:
option 3
Inverter Functions
Description
arithmetic

Advertisement

Table of Contents
loading