Hitachi SJ Series User Manual page 164

Hide thumbs Also See for SJ Series:
Table of Contents

Advertisement

Chapter 12
SM/PMM motor constant parameters
Item
Parameters
Motor constant
[Hd110]
R
Motor constant
[Hd112]
Ld
Motor constant
[Hd114]
Lq
Motor constant
[Hd116]
Ke
Motor constant J
[Hd118]
• The base (max.) frequency can be calculated from
the rated number of revolutions of the motor (min
and the number of poles in the following formula.
Base (max.) frequency (Hz) = rated number of
-1
revolutions (min
) × number of poles (pole)/120
• The motor constant Ke is the peak value of the
phase inducted voltage (mV) per electrical angular
speed (rad/s).
Data
0.000001~1000.000000(Ω)
0.000001~1000.000000(mH)
0.000001~1000.000000(mH)
0.1~100000.0(mVs/rad)
0.00001~10000.00000(kgm
-1
)
12-3-5
Inverter Functions
Description
Sets the resistance of SM/PMM.
Sets the d-axis inductance of
SM/PMM.
Sets the q-axis inductance of
SM/PMM.
Sets the calculated value of induced
voltage of SM/PMM.
Sets the moment of inertia of the
2
)
system.

Advertisement

Table of Contents
loading