Chapter 1
1.7 Response to UL standards
UL CAUTION
GENERAL:
The SJ series Type P1 inverter is an open type AC Inverter
with three phase input and three phase output. It is
intended to be used in an enclosure. It is used to provide
both an adjustable voltage and adjustable frequency to the
ac motor. The inverter automatically maintains the required
volts-Hz ratio allowing the capability through the motor
speed range. It is a multi-rated device and the ratings are
selectable according to load types by operator with key pad
operation.
Markings:
Maximum Surrounding Temperature:
-
ND (Normal Duty) :
-
LD (Low Duty) :
-
VLD (Very Low Duty):
Storage Environment rating:
-
65degC (for transportation)
Instruction for installation:
-
pollution degree 2 environment and Overvoltage
category III
Electrical Connections:
-
See [7.5 Wiring to the main circuit terminal block] of the
users guide.
Interconnection and wiring diagrams:
-
See [7.7 Control circuit terminals] of the basic guide.
50degC
45degC
40degC
1-14