Chapter 12
12.16.4
Preventing restart immediately
after power recovery
Q
How to prevent the motor from starting rotation
suddenly when the inverter power is turned on
How to stop the motor with an error signal when
the power is turned on again while an operation
command is present
A
This function allows you to make the inverter trip
with error code [E13] displayed if the inverter
power is turned on when an operation command
has been turned on.
You can recover the inverter from tripping by
performing the reset operation or turning the
operation command off. (Ex. 1)
If the inverter is recovered from tripping with the
operation command left turned on, the inverter will
start operation immediately after recovery. (Ex. 2)
The inverter can operate normally when an
operation command is turned on after the inverter
power is turned on. (Ex. 3)
(Ex. 1)
Power supply
[FW]
[USP]
[RS]
Alarm
Output speed
Parameter
Item
Input terminal
[CA-01]~[CA-11]
function
(Ex. 2)
Power supply
[FW]
[USP]
[RS]
Alarm
Output speed
Parameter
!
Unlike other types of trip, the USP error [E013]
automatically clears when the operation command
is turned off.
The power recovery restart prevention function
operates for 2 seconds at maximum after the
control power is input.
Power supply
Output speed
Data
[USP]: If the applicable [USP] terminal assigned
to an input terminal has been turned on, the
034
inverter will trip when the power is recovered
while an operation command is present.
12-16-4
Inverter Function
(Ex. 3)
[FW]
[USP]
[RS]
Alarm
Description

Advertisement

Table of Contents
loading