Appendix 1
Parameter mode (code B)
Code
bA101
First frequency upper limit selection
bA102
First frequency upper limiter
bA103
First frequency lower limiter
bA110
First torque limit selection
bA111
First torque limit parameter mode selection
First torque limit 1
bA112
(Four quadrant normal powered)
First torque limit 2
bA113
(Four quadrant reverse rotation regeneration)
First torque limit 3
bA114
(Four quadrant reverse powered)
First torque limit 4
bA115
(Four quadrant normal rotation regeneration)
bA116
First torque LAD stop selection
bA120
First overcurrent suppression selection
bA121
First overcurrent suppression level
bA122
First overload limit 1 selection
bA123
First overload limit level 1
bA124
First overload limit 1 operation time
bA126
First overload limit 2 selection
bA127
First overload limit level 2
bA128
First overload limit 2 operation time
*1) 1.80 × Inverter rated current (A)
*2) 1.50 × Inverter rated current (A)
Name
00 (Disabling)/01 (Ai1 terminal input)/
02 (Ai2 terminal input)/
03 (Ai3 terminal input)/
04 (Ai4 terminal input)/
05 (Ai5 terminal input)/
06 (Ai6 terminal input)/
07 (Parameter setting)/
08 (RS485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)/
12 (Pulse string input (main body))/
13 (Pulse string input P1-FB)
0.00~590.00 (Hz)
0.00~590.00 (Hz)
00 (Disable)/01 (Ai1 terminal input)/
02 (Ai2 terminal input)/
03 (Ai3 terminal input)/
04 (Ai4 terminal input)/
05 (Ai5 terminal input)/
06 (Ai6 terminal input)/
07 (Parameter setting)/
08 (RS 485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)
00 (Four quadrant specific)/
01 ([TRQ] terminal switch)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
0.0~500.0 (%)
(Limited at a torque equivalent to 200%
of inverter ND rating)
00 (Disabled)/01 (Enabled)
00 (Disabled)/01 (Enabled)
(0.00 to 2.00)
× Inverter rated current (A)
00 (Disabled)/
01 (Accelerate at constant speed)/
02 (Only constant speed)/
03 (Accelerate at constant
speed/Increase speed at regeneration)
(0.20 to 2.00)
× Inverter rated current (A)
0.10~3600.00 (s)
00 (Disabled)/
01 (Accelerate at constant speed)/
02 (Only constant speed)/
03 (Accelerate at constant
speed/Increase speed at regeneration)
(0.20 to 2.00)
× Inverter rated current (A)
0.10~3600.00 (s)
Appendix 1-24
Data range
Initial value
List of Parameters
Note
Page
00
0.00
0.00
07
12-11-8
00
12-11-8
150.0
12-11-8
150.0
12-11-8
150.0
12-11-8
150.0
12-11-8
00
12-11-8
01
12-13-3
*1)
12-13-3
01
12-13-2
*2)
12-13-2
1.00
12-13-2
01
12-13-2
*2)
12-13-2
1.00
12-13-2