Chapter 12
12.9.16
Use automatic boost function with
• To conduct a V/f control with a high revolution
accuracy by use of the revolution-speed feedback
of a motor.
• To make the motor follow the command frequency
accurately in applications that require a certain
torque.
• The feedback of the encoder signal from the motor
allows highly accurate frequency control.
• For the adjustment of the automatic boost control,
see, "12.9.7 Automatically adjust torque."
Output
+
Deviatio
frequency
-
Parameter
Item
Control mode
Control with sensor
slip compensation P
gain
Control with sensor
slip compensation
I gain
sensor
PI control
+
1
Kp(1+
)
+
Ti•S
Kp: proportional gain setting; Ti: integral time; s: operator; ε: deviation
Ki: integral gain setting (Ki = Ti/Kp)
Parameter
Data
[AA121]
07
[Hb170]
0~1000(%)
[Hb171]
0~1000(%)
12-9-33
• When [CA-90] = 02, Input terminals [A] and [B] are
switched to the terminals for feedback control.
When [CA-90] ≠ 02, terminals [EA] and [EB] of the
feedback option P1-FB are enabled.
See "12.9.17 Use encoder."
• In the V/f control with feedback (FB), a correction of
PI control is conducted on the command frequency
for the fed-back frequency to control the motor.
Control
frequency
Frequency-volt
age control
To use the automatic torque boost with sensor.
This is the P gain for the slip compensation of
control with sensor.
This is the I gain for the slip compensation of control
with sensor.
Inverter Function
M
Feedback
Description

Advertisement

Table of Contents
loading