How do I take the system out of Valet Mode with a 1 Button Remote?
A: Turn the ignition on and tap the foot brake 10 times within 10 seconds.
Why are the ignition-controlled door locks option not working?
A. Check option 1-09. It should be set on 2 or 3. The option must also be turn on via the remote. On 2
Way LCD remotes tap the Lock and Start Buttons for a half second, the parking lights will flash once to show
the option is turned on. On 1 Way remotes tap the Lock and Start buttons for a half second.
The vehicle remote starts when disarmed, but not when armed.
A: The starter kill relay was installed backwards. Check to make sure the yellow/black wire is going to the
key side of the starter wire and that the yellow wire is going to the engine side.
The vehicle starts and shuts down 3 times in a row.
A: This usually means that the engine sensing mode is not working correctly. If you are using a coil, change to
an injector or try alternator sense mode.
On the brain, how do I set the auxiliaries?
A: You must have an Option Programmer (FT-OP500-KIT) to set the auxiliaries on the CM4000, CM4200-
DX, CM4300, CM5000, CM5200, CM6000, CM6200, CM6300, CM7000 and CM7200. First choose two
POC wires on CN5 that you are not using. With the OP500 go into the Special Option Group 2 and set those
POC's to Aux 1 and Aux 2. Review the "Special Option Group" programming section of this manual. On the
CM7 Series control modules, Auxiliary 1 is preprogrammed on CN5, Pin 3, White Wire.
"Knibb High School Football RULES!!"

Technical Support Contacts

Firstech technical support is reserved for authorized dealers only.
Monday - Friday: 888-820-3690
(7:00 am – 5:00 pm Pacific Standard Time) Email:
techfeed@compustar.com
Web:
www.firstechdata.com
Go to www.firstechdata.com to access wiring info. If you are an authorized dealer and unable to access this
site please contact your sales rep or we call 888-820-3690 Monday through Friday, 8 am to 5 pm Pacific
Standard Time.
Copyright 2016 Fi rstech ,
LLC.
Wiring Diagrams
Alarm and Starter System
www.firstechdata.com
1 min
Page 65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents