CM7 Master Guide
FT-EZGO Setup
The FT-EZGO from Firstech will unlock/disarm the vehicle when in range. It is capable of proximity lock/arm
and unlock/disarm when in or out of range off the vehicle. There is a manual override button located on
the back of the EZ-GO remote. It will lock/arm, unlock/disarm by press and releasing the button for ½ of a
second (0.5 seconds). It will also trigger the trunk release output by press and releasing the button for ½ second
(0.5 seconds) then holding for 2.5 seconds.
Installing The FT-EZGO
STEP 1: Set Option 1-14 to Setting 2, 3 or 4
STEP 2: Connect included Blue 6 Pin (With Ground Wire) to Black 6 Pin to control module. If
connecting to a 4 Pin to 4 Pin antenna, use the included 6 Pin to 4 Pin adapter.
STEP 3: Connect the ground wire from the included 6 Pin to 6 Pin cable to vehicle's ground.
Failure to connect this wire WILL result in damage to your FT-EZGO antenna (ANT- RFID).
STEP 4: If you are using an additional RF kit the antenna cable will connect to the blue 6 pin connector
on the EZ-GO antenna either directly or using the 6 to 4 pin adapter harness included with the EZ-
GO kit.
STEP 5: Find a spot to mount your ANT-RFID on the windshield. This is recommended for optimum
range. For more specific mounting location information visit us at www.firstechdata.com under
the Authorized Tech section document titled: "FT-EZGO Recommended Mounting Locations."
STEP 6: Program your EZ100-R using the standard remote programming procedure along with any
additional RF Kit remotes to the control module (Maximum 4 Remotes including EZ100-R). You
are now ready to test your FT-EZGO system.
Testing The FT-EZGO
STEP 1: Turn the proximity lock/unlock feature on by holding the button on the EZ100-R for 8-10
seconds. You will get one parking light flash and/or siren chirp. To deactivate the proximity
feature simply hold the button again for 8-10 seconds and you will get two parking light flashes
and/or chirps to indicate your feature is off.
STEP 2: Proximity locking/unlocking-The main control module will monitor all of the zone inputs that
are connected analog or data. In order for the proximity Lock/arm function to work all zones
must be closed and ignition off. Once the EZGO remote leaves the proximity of the antenna it
will lock/arm within 15 seconds.
a. the proximity unlock feature will unlock the doors as soon as its within proximity of the
EZGO antenna once the system has proximity locked.