CM7 Master Guide
SV 7 -
FAD (Factory Alarm Disarm):
disarm/unlock command on any POC programmed with this setting.
SV 8 -
provides a 250mA (-) negative output with output control based on feature 3-08 option
Horn:
setting when using any POC programmed with this setting.
SV 9 -
Dome light supervision:
on any POC programmed with this setting, for up to 45 seconds or until ignition is on.
SV 10 -
AUX1:
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 11 -
AUX2:
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 12 -
AUX3:
using a Firstech 2-way LCD remote (please refer to remote users guide for activation steps), on
any POC programmed with this setting.
SV 13 -
AUX4:
with this setting, when AUX4 is triggered using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps),
SV 14 -
AUX5:
with this setting, when AUX5 is triggered, using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps), on any POC programmed with this setting. (Feature 3-
11 must be set to option 2)
SV 15 -
AUX6:
with this setting, when AUX6 is triggered, using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps), on any POC programmed with this setting. (Feature 3-
11 must be set to option 2)
SV 16 -
AUX7:
programmed with this setting, using a Firstech 2-way LCD remote (please refer to remote
users guide for activation steps
SV 17 -
Defrost:
programmed with this setting,
when defrost function has been activated (output time based on features 3-13 and 3-14
option settings)
SV 18 -
GWA (ground While Armed):
programmed with this setting, while the system is armed or locked.
SV 19 -
GWR 2 (status output 2):
programmed with this setting, when the remote start sequence is activated and continue until
after the remote start has shut down.
reservation mode set up to avoid any possible factory immobilizer issue that may occur if the vehicle
sees 2 or more immobilizer override coding.
SV 20 -
Siren 2:
setting, only with the full alarm or panic modes. May be used to power any additional horn or
sirens while the CM7 is in full alarm or panic mode.
SV 21 -
Defrost 2:
setting, when the defrost output is engaged based on the temp setting of feature 3-13.
Copyright 2016 Fi rstech ,
LLC.
provides a 250mA, 800mS (-) negative output with the
provides a 250mA (-) negative output with the disarm/unlock command,
provides a 250mA (-) negative output (based on feature 4-01 setting) when AUX is
provides a 250mA (-) negative output (based on feature 4-02 setting) when AUX is
provides a 250mA (-) negative output (based on AU3 setting) when AUX3 is triggered,
provides a 250mA (-) negative output (based on AU4 setting) on any POC programmed
provides a 250mA (-) negative output (based on AU5 setting) on any POC programmed
provides a 250mA (-) negative output (based on AU6 setting) on any POC programmed
provides a 250mA (-) negative output (based on AU7 setting) on any POC
provides a 250mA (-) negative output (based on feature 3-13/3-14 settings)on any POC
provides a 250mA (-) negative output on any POC
provides a 250mA latched (-) negative output on any POC
provides a 250mA latched (-) negative output on any POC programmed with this
provides a 250mA (-) negative pulsed output only on any POC programmed with this
(Feature 3-11 must be set to option 2)
(Feature 3-11 must be set to option 2)
(Feature 3-11 must be set to option 2)
Note: With GWR 2 the output will not provide ground during
Alarm and Starter System
www.firstechdata.com