Pin 7 Blue - [POC 4] Unlock 250mA, 800mS (-) negative output: This is an optional output that will provide
only a negative (-) output pulse for unlocking doors. System will unlock doors and disarm alarm.
IMPORTANT: You must reverse polarity for (+) trigger door lock systems using the FT-DM700, FT-
DM600 or relays. For additional lock settings review Option Group 1. Note: There are 30 additional
POC setting options for this POC.
Pin 8 Violet/Black - [PIC 2] Trunk zone input (default setting) (-) programmable input: This is an optional
input that will monitor when the vehicle's trunk has been opened. The proper wire will provide a (-)
trigger while the trunk is open. There are additional options for this PIC. Please see Special Options
Group 3.
Pin 9 Orange/White - [POC 5] Factory Alarm Disarm (FAD) 250mA, 800mS negative (-) output: This output
will provide a (-) pulse during unlock and every time prior to the GWR (ground when running: aka. Status
output) turning on during the remote start sequence. It is typically used to disarm factory security systems.
Note: There are 30 additional POC setting options for this POC.
Pin 10 Red/White – [PIC 4] Door zone input (-/+) Jumper programmable polarity: When using (-) jumper
setting this wire can be used as a programmable input channel (PIC). This wire monitors negative
(-) or positive (+) trigger door-pins. The proper wire in the vehicle, will provide a (-) trigger or a (+)
trigger only when the doors are opened. You will need to test the wire for proper polarity and set the
jumper on the control module for the corresponding polarity. There are additional options for this
PIC. Please see Special Options Group 3.
Pin 11 Orange - [POC 6] Factory Alarm Arm (FAA) 250mA, 800mS negative (-) output: This is an optional
output that will provide a (-) pulse during lock, after crank and again after the remote start shuts down.
The FAA output timing can be configured using feature 1-05. Note: There are 30 additional POC
setting options for this POC.
Pin 12 Brown/White - [PIC 3] Key Sense INPUT (-) programmable input: This input can monitor the
keysense provided by the vehicle for manual transmission reservation mode, use of EZGO and/or
Passive arming. There are additional options for this PIC. Please see Special Options Group 3.
-In case of reservation mode for manual transmission the keysense input will not allow the CM7 to
complete reservation mode until the (-) input to the CM7 is removed.
-In case of EZGO the CM7 will monitor all of the Input zones including the (-) keysense input to
make sure the (-) input is removed before it will allow it to proximity lock.
-In case of passive arming the CM7 will monitor the keysense input and not allow the CM7 to
arm/lock passively until (-) input is removed.
Pin 13 Violet/White - [POC 7] Trunk release 250mA, 1 sec. negative (-) output: This is an optional output that
will release the trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System will
unlock doors and disarm alarm prior to trunk release (this procedure is programmable with feature
1-07 and the output time can be changed using feature 1-15). Note: There are 30 additional
POC setting options for this POC.
Copyright 2016 Fi rstech ,