1-16 Siren/Horn mute control: this feature allows the installer to enable or disable the siren/horn mute control.
The mute feature will silence the siren or horn during arm, disarm, and start from the Firstech remote.
FO1 - Disabled: (default) will not allow for the Firstech remote or DroneMobile to mute the siren or
horn output.
FO2 - Enabled: this option will allow the end user to activate or deactivate the arm/disarm chirps using
a Firstech 4/5 button remote or DroneMobile.
FO3 – Silent ALARM:
Firstech 4/5 button remote or Drone Mobile. In this mode the alarm once sounded will be "silent" with no visible
or audible notifications from
remotes that may be in range. This will allow the user to be notified of the alarm sounding without alerting
anyone around the vehicle.
2-01 Tach Threshold: This feature will determine the threshold used to determine the point at which the
CM7 releases the starter based on the sampled tach signal.
FO1 - Optimal Tach reading: This option will allow the CM7 to sample the tach signal several times
during tach programming and select the optimal tach voltage at which to release the starter.
FO2 - Previous tach reading: This option will set the CM7 to record the idle voltage which it is being
programmed. The CM7 will release the starter once the idle tach voltage is met.
2-02 Turbo Timer Mode: (This feature requires door and e-brake input) This feature allows the user to
activate Turbo Timer Mode with their Firstech remote or accessory. This will keep the engine running
after removing the key for the specified time selected below. (Please check specific remote or
accessory user 's manual for steps to activate Turbo Timer Mode)
FO1 - Off: (default)
FO2 - 2 Minutes: This option allows for a 2-minute run time after Turbo Mode has been engaged. To
engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory. Note:
when using Turbo Mode with a manual transmission, the CM7 will not lock the doors automatically.
Before the turbo timer expires, the system must be locked using the Firstech remote or accessory.
FO3 - 1 minute: This option allows for a 1-minute run time after Turbo Mode has been engaged. To
engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory. Note:
when using Turbo Mode with a manual transmission, the CM7 will not lock the doors automatically.
Before the turbo timer expires, the system must be locked using the Firstech remote or accessory.
FO4 - 4 minutes: This option allows for a 4-minute run time after Turbo Mode has been engaged. To
engage, set the e-brake, remove key, exit vehicle, and lock with the Firstech remote or accessory. Note:
when using Turbo Mode with a manual transmission, the CM7 will not lock the doors automatically.
Before the turbo timer expires, the system must be locked using the Firstech remote or accessory.
2-03 Diesel wait to start: Note: OP500 required to adjust time from any of the default settings,
will show up as DISL on the top line of text when option 2 or 3 are enabled. This feature provides a
timed alternative solution to a hard-wired glow plug input to enable the CM7 to wait to start.
FO1 - Wire: (default) This option will allow the CM7 to read input on brown/white wire. (PIC3) It
may be connected to a wait to start indicator on a diesel vehicle. When the CM7 sees (-) negative input,
it will delay the crank output for 99 seconds or until negative signal has been removed.
FO2 - Program (3-99 seconds): default setting is 12 seconds. This option allows the installer to adjust
the time in 1 second increments that the CM7 waits before cranking the starter.
Copyright 2016 Fi rstech ,
LLC.
This option will allow the user to activate or deactivate the arm/disarm chirps using a
the vehicle.
There will be notifications sent to the DroneMobile or 2Way LCD
Alarm and Starter System