Firstech CM-7000 Master Manual page 37

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
1-13 Double pulse disarm: This feature enables the FAD output. It will pulse 2 times with a single disarm
command.
FO1 - Off (default): Standard single pulse output on the FAD wire. (orange/white by default)
FO2 - On: This feature will generate a double pulse output on the FAD wire. (orange/white by
default)
1-14 EZGO RFID Function: This feature covers the EZGO options. (Please refer to the EZGO
section of this manual for specific operation instructions and antenna mounting locations)
FO1 - Off (default): No EZGO functions are enabled by default.
FO2 - FTX EZGO "always unlock": This option will enable the EZGO proximity unlock feature after
activating with the EZ100-R remote. (Refer to the EZGO section of this manual for specific operating
instructions) The CM7 will always send the unlock/disarm output when the EZ100-R enters the
proximity field regardless of the current state of the CM7. (i.e. armed/locked-disarmed/unlocked). Once
the EZ100-R leaves the proximity field, it will be set to send the unlock/disarm output as soon
as it re-enters. Note: because the EZGO antenna is always searching for the EZ100-R, it will produce
more current draw than the standard EZGO unlock option 3.
FO3 - EZGO "unlock only": (The CM7 must be in an armed state for this option) This option will
enable the EZGO proximity unlock/disarm feature after activating with the EZ100-R remote. (Refer to
the EZGO section of this manual for specific operating instructions). The CM7 will be ready to send the
disarm/unlock command 12-15 seconds after the system has been armed using
a Firstech remote or accessory (RPS, Drone, OEM remote input). Once the EZGO system is ready and the
remote enters the proximity field, it will unlock/disarm.
FO4 - EZGO lock and unlock: This option will enable the EZGO proximity lock/arm and unlock/
disarm features once it's activated using the remote. (Refer to the EZGO section of this manual for
specific operation instructions.) The EZGO will arm/lock approx. 12-15 seconds after the RFID remote
leaves proximity of the EZ-GO antenna and all zones being monitored (including any key sense or
ignition inputs) are closed or off. As soon as the CM7 is armed/locked the proximity unlock is active and
will unlock/disarm as the EZGO remote enters the proximity field. Note: because the EZGO antenna is
always searching for the EZ100-R, it will produce more current draw than the standard EZGO unlock
option 3.
1-15 Trunk Output Timing: This feature determines the length of output time for the (+) or (-) analog trunk
release wire.
FO1 - 1 Second: (default) Will provide a 250mA (-) negative output for 1 second on any POC that is
programmed for trunk release or setting 28.
FO2 - 2 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 2 seconds on
any POC that is programmed for trunk release or setting 28.
FO3 - 3 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 3 seconds on
any POC that is programmed for trunk release or setting 28.
FO4 - 4 Seconds: FO1- 1 Second: (default) will provide a 250mA (-) negative output for 4 seconds on
any POC that is programmed for trunk release or setting 28.
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents