Special Option Groups 1, 2, And 3 - Firstech CM-7000 Master Manual

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
FO2 - On: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when the
vehicle's battery voltage (at the CM7 power connector) drops to 11.7volts. Note: the Firstech 2-way
LCD remote must be within range of the vehicle to receive the low battery alert and this option must
be set to receive low battery alerts to Drone.
FO3 - On + Start: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when
the vehicles battery voltage (at the CM7 power connector) drops to 11.7volts. In addition to the alert the
user can active the Timer mode (please refer to this manual for timer mode feature description) to
enable the low battery start function. Once the timer mode is active the CM7 will adhere to the timer
mode feature options selected but also monitor the vehicle battery voltage which will override the timer
mode and start at 11.7 volts.
4-15 Door Status Input: This Feature has been removed please see Special Options group 3 PIC settings
for more options

Special Option Groups 1, 2, and 3

IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2. Special
Option Group 1
SO1- Diesel Timer: (Option 2-03 must first be set to setting 2.) This special option allows a specific
wait to start time (in seconds) to be programmed. This prevents the need for a timer relay and eliminates
a connection to the "wait to start" wire.
SO2 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option allows a
specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500 update to software
v.30, latched output time 1-15 minutes are available for programming in addition to the standard 1-99
seconds.
SO3 - Aux 2 Output Timing: (Option 4-02 must first be set to setting 4.) This special option allows a
specific output duration for Aux 2 to be programmed 1-99 seconds. Note with OP500 update to software
v.30, latched output time 1-15 minutes are available for programming in addition to the standard 1-99
seconds.
SO4 - SO8 - Aux 3-7 Output Timing: (Option 3-11 must first be set to setting 2 and the optional
Auxiliary settings module must be used and AUX 3-7 function only available with 2 Way LCD remotes)
These special options allow specific output durations to be set for Aux 3-7. Note with OP500 update to
software v.30, latched output time 1-15 minutes are available for programming in addition to the
standard 1-99 seconds.
NEW* SO9- Remote Start Runtime: (Feature 2-07 must first be set to option 4.) This special option allows a
custom Remote start time (in minutes up to 45 minutes) to be programmed. The default runtime is 3
minutes.
NEW* SO10- Cold Start Temperature: (Feature 2-08 must first be set to option 4.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between -30 ~ 0 [°C] / -22 ~ 32 [°F] with a default temperature of -15°C / 5°F default for the Cold Start
Timer mode activation
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents