Firstech CM-7000 Master Manual page 28

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
Connector 12 (CN12), 2-Pin (Pre-wired LED) **WHITE connector Note: Do not mistake for Thermistor
port. Note: The LED will stay solid blue when armed for the duration of the sensor set up time. (Approx.
25 seconds)
Pin 1 Black - L.E.D negative (-) ground.
Pin 2 Black/White- L.E.D. 2.5V positive (+) output.
Connector 13 (CN13), 4-Pin (Pre-wired RPS Touch or RPS 2)
Pin 1 Black - Negative (-) ground.
Pin 2 White - Negative (-) paging input.
Pin 3 Red - 12V positive (+) output.
Pin 4 Yellow - 9V positive (+) L.E.D. output.
Connector 14 (CN14), 4-Pin (Pre-wired DAS Sensor)
Pin 1 Black - Negative (-) ground when armed (GWA).
Pin 2 White - 2nd stage negative (-) input. (Instant trigger)
Pin 3 Red - 12V positive (+) output.
Pin 4 Yellow - 1st stage negative (-) input. (Warn away)
Connector 15 (CN14), 4-Pin (Optional Sensor Input)
This connector provides optional sensor inputs. Most commonly used with proximity and tilt
sensors.
Pin 1 Black – Negative (-) ground.
Pin 2 Black/White [PIC 7] – AUX input (INSTANT TRIGGER): This wire default setting will trigger to full
alarm, the CM7000 security system if ground (-) is applied momentarily. This wire can be
programmed to offer other input functions based on the PIC setting value in special options group
3; using the OP500
Pin 3 Red – 12V positive (+) output.
Pin 4 Grey/White [PIC 6]– AUX Input (PREWARN): This wire default setting will trigger the CM7000
security system prewarning chirps/horn honks if ground (-) is applied momentarily. This wire can be
programmed to offer other input functions based on the PIC setting value in special options
group 3; using the OP500
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents