Firstech CM-7000 Master Manual page 56

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
PIC setting value description (SV)
SV 1 - (-) E-Brake INPUT: This setting allows any PIC programmed with value 1 to be used as a (-)
negative parking /emergency brake INPUT.
SV 2 - (-) Trunk Status INPUT: This setting allows any PIC programmed with value 2 to be used
as a (-) negative Trunk status INPUT. This can be used as a single trunk or multi rear door input
for security or Manual transmission remote start.
SV 3 - (-) Key-Sense INPUT: This setting allows any PIC programmed with value 3 to be used as a (-)
negative Key-sense INPUT. Keysense is recommended when remote starting manual transmission
vehicle.
SV 4 - (-) Hood Status INPUT: This setting allows any PIC programmed with value 4 to be used as a (-)
negative Hood Status INPUT. This can be used as a single hood pin input for security or Manual
transmission remote start.
SV 5 - (-) Door Status INPUT: This setting allows any PIC programed with value 5 to be used as (-)
negative Door Status. This can be used as a single door or multi door input for security or
Manual transmission remote start.
SV 6 - (-) Trigger Start INPUT: This setting allows for any PIC programmed with value 6 to be
used as a (-) negative Remote Start Trigger Start INPUT.
SV 7 - (-) Glow Plug INPUT: This setting allows for any PIC programmed with value 7 to be used as a
Glow Plug INPUT for diesel wait to start function.
SV 8 - (-) Disable ARM/Disarm/Start INPUT: This setting allows any PIC programmed with value 8
to be used as a (-) negative arm/disarm/start disable INPUT when controlling the CM through
analog arm/disarm/start inputs. (will disable the analog disarm input command if ground is
present on both disarm input wire and disarm disable input wire simultaneously)
SV 9 - (N/C) Trunk INPUT: This setting allows any PIC programmed with value 9 to be used as a
Normally Closed-circuit Trunk pin INPUT. The CM will consider the zone open when ground is
removed or the circuit status changes from (-) ground to power. This can be used as a single
trunk zone input for security or remote start
SV 10 - (N/C) Key Sense INPUT: This setting allows any PIC programmed with value 10 to be used as a
Normally Closed-circuit Key Sense Input. The CM will consider the key to be in the key
cylinder if when ground is removed or the circuit status changes from (-) ground to power.
Keysense is recommended when remote starting manual transmission vehicle.
SV 11 - (N/C) Hood Status: This setting allows any PIC programmed with value 11 to be used as a
normally closed-circuit hood pin INPUT. The CM will consider the zone open when ground is
removed or the circuit status changes from (-) ground to power. This can be used as a single
hood zone input for security or remote start
SV 12 - (N/C) Door INPUT: This setting allows any PIC programmed with value 12 to be used as a
normally closed-circuit door pin INPUT. The CM will consider the zone open when ground is
removed or the circuit status changes from (-) ground to power. This can be used as a SINGLE
(1) door zone input for security or remote start.
SV 13 - (-) Pre-Warn INPUT: This setting allows any PIC programmed with value 13 to be used as an
Auxiliary sensor prewarn Input. Once Armed the CM will activate the prewarn chirps if this
input sees ground/negative input.
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 56

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents