Firstech CM-7000 Master Manual page 45

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
FO2 - On: this option will enable the anti-carjacking feature. Make sure the starter interrupt relay is
wired to interrupt the vehicle's ignition wire, so the feature will operate as described. While the vehicle
is running with the key and the panic mode is activated using any Firstech 4 button or 2-way LCD
remote, the CM7 will enable the ignition interrupt relay so the vehicle cannot be re-started. Note:
When using ignition-kill on manual transmission vehicles feature 3-04 must be set to option
2 will need to be utilized. this disables the anti-grind circuit while the vehicle is remote-started; if the
anti-grind circuit is active and the start-kill relay is installed in the ignition, the relay will "buzz" while
remote-started.
3-06 Security Features: This feature will enable or disable the security features of the CM7000, or CM7200.
Security features include sensor inputs, zone inputs (unless using with manual transmission), horn, and
siren output. Basic features will function normally (lock, unlock, trunk release, remote start, parking
lights.) Please note the control module model when determining the correct feature option.
FO1 - On: (default CM7000)/ FO1- OFF: (default CM7200) Depending on the Control Module this
option will enable or disable the security features.
FO2 - Off: (CM7000 default)/ FO2- ON: (CM7200) Depending on the Control Module this option
will enable or disable the security features.
3-07 Siren Duration: this feature changes the duration of the siren during full alarm.
FO1 - 30 seconds: this option will provide 30 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO2 - 60 seconds: this option will provide 60 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO3 - 120 seconds: this option will provide 120 seconds of output (+) on the siren wire (brown
CN5) during full alarm.
FO4 - Chirps for 20 seconds: this option will provide 20 seconds of pulsed output (+) on the siren
wire (brown CN5) during full alarm.
3-08 Horn output: This feature controls the horn output behavior during Arm, Disarm, and Remote Start.
(POC 2 White wire or POC setting #8)
FO1 - On double lock only: (default) this option is designed to simulate a factory keyless entry system
by providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.
FO2 - On lock and Unlock only: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
FO4 - On double lock and Start: this option is designed to simulate a factory keyless entry system by
providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition, it will provide a horn output
pulse with remote start command and remote started confirmation.
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 45