CM7 Master Guide
1-09 Ignition Controlled Locks (DRIVE LOCK): When FO 2-4 are selected, the user can activate the "drive
lock" or ignition-controlled door locking feature using a Firstech remote or Drone. (Please check specific
remote user 's manual for steps to activate Drive lock.)
FO1 - Off: (default)
FO2 - On: This option (when activated with the Firstech remote or Drone) will provide a door lock
output when the foot brake is applied, or 12 Volts is applied to the foot brake input on the CM7. The CM7
will also provide a door unlock output as soon as the key is turned off or the parking brake is set (must
have parking brake input connected or provide parking brake input from data module)
FO3 - RPM locking: (Tach input is required for this option to operate properly.) This option will
provide a door lock output at approximately 20% RPM over the programmed idle tach output. (i.e.
program tach at 1000 rpm and doors will lock at a sustained 1200 rpm when moving.) The CM7 will
also provide a door unlock output as soon as the key is turned off or the parking brake is set (must
have parking brake input connected or provide parking brake input from data module)
1-10 Auto Relock:
FO1 - Off: (default)
FO2 - 30 seconds: This option allows the CM7 to automatically relock/rearm 30 seconds after
CM7 has been disarmed/unlocked. This will only happen if no zones have not been opened.
FO3 - 60 seconds: This option allows the CM7 to automatically relock/rearm 60 seconds after
CM7 has been disarmed/unlocked. This will only happen if no zones have not been opened.
FO4 - 5 minutes: This option allows the CM7 to automatically relock/rearm 5 minutes after it has been
disarmed/unlocked. This will only happen if no zones have not been opened.
1-11 Ignition / Accessory Upon Unlock: This feature will provide an Ignition/Accessory output with unlock/disarm
command. (NOTE: will not provide pulse output with disarm before remote starting)
FO1 - Off: (default)
FO2 - Ignition (+) and (-) pulse output with disarm: This option will pulse both (+) and (-) ignition
wires upon unlock/disarm. Most new Ford vehicles require ignition pulsed + immobilizer with unlock
to disarm the factory alarm.
FO3 - Accessory (+) and (-) pulse output with disarm: This option will pulse both (+) and
(-) accessory wires upon unlock/disarm.
FO4 - Ignition (+) and (-) pulse and Accessory (+) and (-) pulse output with disarm: This option will
pulse both (+) and (-) ignition and accessory wires upon unlock/disarm. Some new Ford vehicles
require ignition and accessory pulsed + immobilizer with unlock to disarm the factory alarm.
Important: Also used in cases where the vehicle's radio may turn on and stay on until the door is opened
when accessory is pulsed.
1-12 OEM Remote status update: This feature disables the arming, disarming, and remote start
confirmation updates to any Firstech 2 Way LCD when using an OEM remote.
FO1 - On: (default)
FO2 - Off: This feature disables the page back update to the 2 Way Firstech remote when your
interface module provides OEM remote status updates to the CM7.