Firstech CM-7000 Master Manual page 25

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
Pin 14 Pink - Trigger Start (+) programmable input. This is an input (+) that can be used to activate the start
sequence when triggered 1, 2, or 3 times based on option selected on feature 2-04. This
can be done with a door lock motor output being operated by a factory keyless entry or another
external source. There are additional options for this Input please check feature 4-10.
Pin 15 Black - [POC 8] Status/Ground while running (GWR) 250mA latched negative (-) output: This is an
optional output that will provide a latched negative (-) output 250mS before the ignition turns on, stays
on throughout the remote start duration and will be the last to shut off. This wire is most commonly used
to trigger bypass / transponder modules. Note: There are 30 additional POC setting options for
this POC.
Pin 16 Gray/Black - [PIC 5] Hood Pin negative (-) (default setting) input: This input is a safety shut down and
alarm trigger. It prevents the vehicle from remote starting while the hood is open and triggers the alarm if the
hood is opened while the alarm is armed. You can connect this wire to the hood pin supplied with this
kit, or to a wire in the vehicle that shows (-) only while the hood is open. There are additional
options for this PIC, please see Special Options Group 3.
Pin 17 Green/White - (fixed output) Parking light 250mA negative (-) output. This will provide output
whenever the parking lights are activated for lock, unlock, remote start, diagnostics, and
programming the proper wire in the vehicle will test (-) when the parking light switch is in the on
position.
Pin 18 Yellow/Black - Engine sensing input (A/C): This wire is connected to the vehicle's Tach or Alternator
wire and is required when using the tach and alternator sense setting. (You can also connect this wire to
the battery (+) post when using voltage sense to make it more accurate) IMPORTANT: To change
engine-sensing modes, you must change Option 2-10; Default option is set for tach input.
Pin 19 Red/Black - (fixed output) 2nd Starter output 250mA negative (-) output. This output provides a (-)
negative start output during the crank period of the remote start process.
Pin 20 White/Black - (fixed output) 2nd Accessory 250mA negative (-) output. This output provides a (-)
negative accessory output that will drop out during the crank period of the remote start process.
Connector 6 (CN6), Grey 4 Pin (UART data port) Drone/Fortin data to data only
Pin 1 (B+) - Constant 12V positive (+) output
Pin 2 (B-) - Ground (-) output
Pin 3 (RX) - Input, this wire receives data
Pin 4 (TX) - Output, this wire transmits data
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents