Firstech CM-7000 Master Manual page 46

Hide thumbs Also See for CM-7000:
Table of Contents

Advertisement

CM7 Master Guide
3-09 Siren output: This feature controls the siren (+) output behavior during Arm, Disarm, and Remote
Start.
FO1 - On lock, Unlock, and Start: (default) this option will provide a (+) siren output pulse (based
on the option selection of feature 3-02) with each lock, unlock, remote start command and remote
started confirmation.
FO2 - On double lock only: This option is designed to simulate a factory keyless entry system by
providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.FO3 - On lock and Unlock
only: this option will provide a (+) siren output pulse (based on the option selection of feature 3-02)
with each lock or unlock confirmation.
FO4 - On double lock and Start: this option is designed to simulate a factory keyless entry system by
providing a (+) siren output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition, it will provide a (+) siren output
pulse with remote start command and remote started confirmation.
3-10 Valet Mode: This feature will change the enter/exit valet mode procedure based on the option
selected.
FO1 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk) while Ignition is on: This
option allows the user to enter valet mode using either method described. Note: the user may exit valet
mode with their Firstech remote (please check users guide for each remote for valet mode exit
procedure), or with the key to ignition or "on" position
and press the foot brake 10 times within 10 seconds.
FO2 - Key 5 times with Foot Brake Trigger or Remote (Lock + Trunk): This option allows the user to
enter valet mode using either method described. Note: the user may exit valet mode with their Firstech
remote (please check users guide for each remote for valet mode exit procedure), or with the key to
ignition or "on" position and press the foot brake
10 times within 10 seconds.
3-11 Auxiliary 3-7 Enable: (2 Way LCD remote required) this feature enables access to AUX 3 through 7
via any Firstech 2-way LCD remote.
FO1 - Off: (Default) This option will prevent the user form activating AUX 3-7 with the Firstech 2way
LCD remote.
FO2 - On: This feature will allow the user to enable AUX 3-7 which can be activated using a Firstech
2-way LCD remote. (Please refer to the remote users guide for specific AUX 3-7 activation process)
3-12 VAC: (thermistor required) this determines the temperature at which the CM7 will provide an output on
any POC programmed with setting 22(VAC: Ventilation-Air Conditioning) which can be used to vent
widows, activate AC controls, or cooling seats.
FO1 - 100°F: This option will provide a pulsed output on any POC programmed with setting 22
(VAC) if the temp sensor reads at or above 100°F with remote start confirmation.
FO2 - 90°F: This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 90°F with remote start confirmation.
Copyright 2016 Fi rstech ,
LLC.
Alarm and Starter System
www.firstechdata.com
Page 46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents