:MODE?
:SLOPe[<n>]
Parameters
Note
Comments
96 Digitizer Command Reference
MASTer<n> and SLAVe<n> pairs a sample line and a trigger line which are
then used for multiple unit synchronization. See the section titled "Master-
Slave Operation" in Chapter 2 for more information including diagrams.
MASTer MODE
MASTer0
MASTer2
MASTer4
MASTer6
Executable when initiated: Yes
Coupled command: No
Reset (*RST) condition: NORMal mode
TRIGger:MODE? queries the trigger mode setting. Returns NORMal, MASTer
or SLAVe.
TRIGger:SLOPe[<n>] POS | 1 | NEG | 0 sets the active edge of the trigger signal
which causes a measurement to be made. There are two trigger sources and you must
designate which source you are setting the slope. n = 1 for the slope of trigger source
number 1. n = 2 for the slope of trigger source number 2. Trigger slope defaults to
n=1 if "n" is not designated.
Parameter
Name
n
Trigger slope is active only when the trigger source is one of the four INTernal
levels (TRIG:SOURce INT1-4) or when the EXTernal trigger source is specified
(TRIG:SOURce EXTernal).
Executable when initiated: Yes
Coupled command: TRIG:SOURce INT1-4 and TRIG:SOURce EXTernal
TTLT pairs to SLAVe modules
SLAVe MODE
Sample line
SLAVe0
SLAVe2
SLAVe4
SLAVe6
Parameter
Range of
Type
numeric
Trigger line
TTLT0
TTLT1
TTLT2
TTLT3
TTLT4
TTLT5
TTLT6
TTLT7
Default
Values
Units
1 or 2
None