Replacing A Call Records Server Disk - 3Com VCX V7000 Installation Manual

Ip telephony solution system release 9.0
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

412
A
B: R
PPENDIX
EPLACING A
Replacing a Call
Records Server Disk
F
D
VCX S
AILED
ISK ON A
b Enter these commands:
cd /opt/3com/VCX/scripts/rc3.d
./S20vcxdata start
25 Wait for at least 30 minutes and verify that database replication has been
completed for the remote regional office and for each branch office.
26 After database replication has been completed for all databases, start
Tomcat on both region Call Processing Servers and at all branch offices.
a On the Call Processing Server in the remote regional office, log in as
root.
b Enter these commands:
service vcxtomcat start
c On the Call Processing Server in the local regional office, log in as root.
d Enter these commands:
service vcxtomcat start
e On each branch office server, log in as root.
f Enter these commands:
service vcxtomcat start
This marks the end of the outage.
Each multi-site VCX system has one Call Records Server that is located in
one of the regional offices. Use the instructions in this section to replace a
failed disk on a Call Records Server.
If this server is configured for RAID operation, see
earlier in this appendix.
1 Replace the failed disk.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
2 Configure the networking and services parameters on the down server
using this command:
ERVER
RAID Disk
Failure,

Advertisement

Table of Contents
loading