Instructions (Single Site, Four Servers) - 3Com VCX V7000 Installation Manual

Ip telephony solution system release 9.0
Hide thumbs Also See for VCX V7000:
Table of Contents

Advertisement

386
A
B: R
PPENDIX
EPLACING A
Instructions
(Single Site,
Four Servers)
F
D
VCX S
AILED
ISK ON A
Use the instructions in this section to replace the disk on a:
Primary or Secondary IP Telephony Server
Primary or Secondary IP Messaging Server
1 If the server is configured for RAID operation, see
earlier in this appendix.
1 Replace the failed disk.
a Remove power from the down server.
b Remove the failed disk.
c Install the replacement disk.
d Apply power to the server.
e Press the start button on the front panel.
2 Log in as root and configure the networking parameters on the down
server using this command:
vcx-config-network --wizard
If the down server is the Primary IP Telephony Server, follow the
instructions in
Configuring a Primary IP Telephony Server (Single Site)
Chapter
3.
If the down server is the Secondary IP Telephony Server, follow the
instructions in
Configuring a Secondary IP Telephony Server (Single Site)
in
Chapter
3.
If the down server is the primary IP Messaging Server, follow the
instructions in
Configuring a Primary IP Messaging Server
If the down server is the Secondary IP Messaging Server, follow the
instructions in
Configuring a Secondary IP Messaging Server
3 If necessary, upgrade the software version on the down server to match
the software version on the running server.
a Compare the software version on the down server to the software
version on the running server.
On the running server and on the down server, enter this command:
vcx-showversion
b If the down server is running an earlier software version than the
running server, download the appropriate software upgrade file to the
/opt/installtemp
ERVER
directory on the down server.
RAID Disk
Failure,
in
in
Chapter
4.
in
Chapter
4.